UMTS/HSDPA Module
UC15 Hardware Design
UC15_Hardware_Design Confidential / Released 29 / 72
+QIND: “vbatt”,1
The uncritical voltage is 3.3V to 4.4V, If the voltage > 4.4V or < 3.3V the module would automatically shut
down itself.
If the voltage < 3.3V, the following URC will be presented:
+QIND: “vbatt”,-2
If the voltage > 4.4V, the following URC will be presented:
+QIND: “vbatt”,2
The value of voltage threshold can be revised by AT command, refer to
document [1]
for details.
3.8. Reset the Module
The RESET_N can be used to reset the module.
Table 9: RESET_N pin description
Pin Name Pin No.
Description
DC Characteristics
Comment
RESET_N 17
Reset the module.
V
IH
max = 2.1V
V
IH
min = 1.6V
V
IL
max = 0.3V
Pull-up to 1.8V internally
Active low.
You can reset the module by driving the RESET_N to a low level voltage and then releasing.
The recommended circuit is similar to the PWRKEY control circuit. You can use open drain/collector
driver or button to control the RESET_N.
NOTE