background image

                                                                                             

           

NB-IoT  Module  Series 

                                                                                                                                BC95  Hardware  Design

 

BC95_Hardware_Design                                  Confidential / Released                                                29 / 51 

 

 

 

HIGH

LOW

RI

120ms

Idle 

A URC or SMS message is received

 

Figure 14: Behaviors of RI When a URC or SMS Message is Received 

 

 

“*” means under development.   

 

3.12. Network Status Indication* 

 

The NETLIGHT signal can be used to drive a network status indication LED. The working state of this pin 

is listed in the following table. 

 

Table 13: Working State of the NETLIGHT 

 

 

 

 

 

 

 

 

 

 

 

State 

Module Function 

Low (Light off) 

The module is not working or not attached to network. 

High (Light on) 

The module is attached to network. 

NOTE 

Quectel 

Confidential

Summary of Contents for BC95

Page 1: ...BC95 Hardware Design NB IoT Module Series Rev BC95_Hardware_Design_V1 3 Date 2017 06 15 www quectel com...

Page 2: ...ATION PROVIDED IS BASED UPON CUSTOMERS REQUIREMENTS QUECTEL MAKES EVERY EFFORT TO ENSURE THE QUALITY OF THE INFORMATION IT MAKES AVAILABLE QUECTEL DOES NOT MAKE ANY WARRANTY AS TO THE INFORMATION CONT...

Page 3: ...eted information of SWD interface 2 Modified typical supply voltage of the module 3 Added the power saving information 4 Modified the UART level match circuit 5 Updated bottom dimensions of the module...

Page 4: ...18 3 5 Power Supply 18 3 5 1 Power Supply Pins 18 3 5 2 Reference Design for Power Supply 19 3 6 Power on and down Scenarios 19 3 6 1 Power on 19 3 6 2 Power down 20 3 6 3 Reset the Module 20 3 7 Powe...

Page 5: ...mum Ratings 38 5 2 Operating Temperature 38 5 3 Current Consumption 39 5 4 Electrostatic Discharge 40 6 Mechanical Dimensions 41 6 1 Mechanical Dimensions of the Module 41 6 2 Recommended Footprint 43...

Page 6: ...NITION OF THE USIM CARD INTERFACE 26 TABLE 11 PIN DEFINITION OF THE ADC 28 TABLE 12 BEHAVIORS OF RI 28 TABLE 13 WORKING STATE OF THE NETLIGHT 29 TABLE 14 PIN DEFINITION OF THE RF ANTENNA INTERFACE 31...

Page 7: ...RS OF RI WHEN A URC OR SMS IS RECEIVED 29 FIGURE 15 REFERENCE DESIGN FOR NETLIGHT 30 FIGURE 16 REFERENCE DESIGN FOR RF 31 FIGURE 17 MICROSTRIP LINE DESIGN ON A 2 LAYER PCB 32 FIGURE 18 COPLANAR WAVEGU...

Page 8: ...its air interface and hardware interface which are connected with customers applications This document can help customers to quickly understand module interface specifications electrical and mechanica...

Page 9: ...oarding the aircraft if your device offers an Airplane Mode which must be enabled prior to boarding an aircraft Switch off your wireless device when in hospitals clinics or other health care facilitie...

Page 10: ...le with LCC package with an ultra compact profile of 19 9mm 23 6mm 2 2mm which can be easily embedded into applications It provides hardware interfaces such as ADC and UART interfaces and can meet alm...

Page 11: ...transmission and the baud rate is 9600bps Main port can also be used for firmware upgrading and the baud rate is 115200bps Debug port Debug port is used for debugging Only support 921600bps baud rate...

Page 12: ...their value and exceed the specified tolerances When the temperature returns to the normal operating temperature levels the module will meet 3GPP specifications again 3 means under development 2 3 Fu...

Page 13: ...nfidential Released 12 51 2 4 Evaluation Board In order to help customers to develop applications with BC95 Quectel supplies the evaluation board EVB RS 232 to USB cable power adapter antenna and othe...

Page 14: ...unctions 3 1 General Description BC95 is equipped with 54 pin 1 1mm pitch SMT pads plus 40 pin ground reserved pads The following chapters provide detailed descriptions of these pins Power supply UART...

Page 15: ...NETLIGHT DBG_RXD DBG_TXD ADC RESERVED RESERVED RESERVED RESERVED VDD_EXT RESERVED USIM_CLK USIM_DATA USIM_RST USIM_VDD RI RESERVED RESERVED TXD RXD RESERVED USIM_GND GND RESERVED RESERVED RESERVED GN...

Page 16: ...AO Analog output OD Open drain Table 4 Pin Description Power Supply Pin Name Pin No I O Description DC Characteristics Comment VBAT 45 46 PI Main power supply of the module VBAT 3 1V 4 2V Vmax 4 2V V...

Page 17: ...rface Pin Name Pin No I O Description DC Characteristics Comment ADC 21 AI General purpose analog to digital converter interface Input voltage range 0V to VBAT If unused keep this pin open UART Port P...

Page 18: ...odule pad to USIM card connector is 200mm USIM_ RST 39 DO USIM card reset VOLmax 0 4V VOHmin 2 4V USIM_ DATA 40 IO USIM card data VOLmax 0 4V VOHmin 2 4V VILmin 0 3V VILmax 0 6V VIHmin 2 1V VIHmax 3 3...

Page 19: ...45 46 Power supply for the module 3 1 3 6 4 2 V Mode Function Normal Operation Active In active mode all functions of the module are available and all processors are active Radio transmission and rec...

Page 20: ...rom 3 1V to 4 2V Please make sure that the input voltage will never drop below 3 1V even in burst transmission If the power voltage drops below 3 1V the module will be abnormal For better power perfor...

Page 21: ...y shutting down the VBAT power supply VBAT RESET Delay 5ms Figure 5 Turn off Timing 3 6 3 Reset the Module The module can be reset by two ways The reset timing is illustrated as the following table Ha...

Page 22: ...or button can be used to control the RESET pin Reset pulse RESET 4 7K 47K Figure 6 Reference Circuit of RESET by Using Driving Circuit RESET S1 Close to S1 TVS Figure 7 Reference Circuit of RESET by...

Page 23: ...ote that the module cannot request PSM when it is establishing an emergency attachment or initializing the PDN Public Data Network connection When the module is in PSM it cannot be paged and stops acc...

Page 24: ...rate is 9600bps It can also be used for firmware upgrading through Universal Code Loader or Code Loader tool and the baud rate for firmware upgrading is 115200bps This main port is available in activ...

Page 25: ...l port Main port GND GND PC DTE Figure 9 Reference Design for Main Port 3 8 2 Debug Port Debug port is used to view log information with UE Log Viewer tool for debugging and the baud rate is 921600bps...

Page 26: ...commended to add a resistor with resistance greater than 1K on the UART port signal traces when the host s voltage level is 3V or 3 3V 2 For systems with a higher voltage level a level shifter IC coul...

Page 27: ...level shifter IC such as http www exar com and http www maximintegrated com 3 9 USIM Card Interface The module contains one USIM interface to allow the module to access the USIM card 3 9 1 USIM Card...

Page 28: ...AT traces Assure the ground between module and USIM card connector short and wide Keep the trace width of ground no less than 0 5mm to maintain the same electric potential The decouple capacitor of US...

Page 29: ...voltage value This ADC interface is available in active mode and idle mode Table 11 Pin Definition of the ADC means under development 3 11 Behaviors of RI When an SMS message is received or certain UR...

Page 30: ...Received means under development 3 12 Network Status Indication The NETLIGHT signal can be used to drive a network status indication LED The working state of this pin is listed in the following table...

Page 31: ...ardware Design BC95_Hardware_Design Confidential Released 30 51 A reference circuit is shown as below Module NETLIGHT 4 7K 47K 2 2K VBAT Figure 15 Reference Design for NETLIGHT means under development...

Page 32: ...enna interface has an impedance of 50 Table 14 Pin Definition of the RF Antenna Interface 4 1 RF Antenna Reference Design A reference design for RF antenna is shown as below RF_ANT 0R NM NM Module Fig...

Page 33: ...CB the characteristic impedance of all RF traces should be controlled as 50 ohm The impedance of the RF traces is usually determined by the trace width W the materials dielectric constant the distance...

Page 34: ...RF pins should not be designed as thermal relief pads and should be fully connected to ground The distance between the RF pins and the RF connector should be as short as possible and all the right ang...

Page 35: ...compliant with the NB IoT radio protocol 3GPP Rel 13 4 4 RF Receiving Sensitivity Table 16 RF Receiving Sensitivity Throughput 95 Frequency Band Max Min Band 8 23dBm 2dB 40dBm Band 5 23dBm 2dB 40dBm B...

Page 36: ...tenna Table 18 Antenna Cable Requirement Frequency Range Requirement 758 960MHz Insertion Loss 1dB Table 19 Antenna Requirements Type Requirements Frequency Range 758 960MHz VSWR 2 Gain dBi 1 Max Inpu...

Page 37: ...ollowing figure is the antenna installation with RF connector provided by HIROSE The recommended RF connector is UF L R SMT Figure 21 Dimensions of the UF L R SMT Connector Unit mm U FL LP series conn...

Page 38: ...gn BC95_Hardware_Design Confidential Released 37 51 The following figure describes the space factor of mated connector Figure 23 Space Factor of Mated Connector Unit mm For more details please visit h...

Page 39: ...lowing table Table 20 Absolute Maximum Ratings 5 2 Operating Temperature The operating temperature is listed in the following table Table 21 Operating Temperature Parameter Min Max Unit VBAT 0 3 4 25...

Page 40: ...m to radio network Only one or more parameters like Pout might reduce in their value and exceed the specified tolerances When the temperature returns to the normal operating temperature levels the mod...

Page 41: ...ly apply to ESD sensitive components Proper ESD handling and packaging procedures must be applied throughout the processing handling and operation of any application that incorporates the module The f...

Page 42: ...6 Mechanical Dimensions This chapter describes the mechanical dimensions of the module All dimensions are measured in mm The tolerances for dimensions without tolerance values are 0 05mm 6 1 Mechanic...

Page 43: ...NB IoT Module Series BC95 Hardware Design BC95_Hardware_Design Confidential Released 42 51 Figure 25 Module Bottom Dimensions Bottom View Quectel Confidential...

Page 44: ...l Released 43 51 6 2 Recommended Footprint Figure 26 Recommended Footprint Top View 1 For easy maintenance of the module please keep about 3mm between the module and other components in the host PCB 2...

Page 45: ...eleased 44 51 6 3 Design Effect Drawings of the Module Figure 27 Top View of the Module Figure 28 Bottom View of the Module These are design effect drawings of BC95 module For more accurate pictures p...

Page 46: ...ry environment of 30 C 60 RH Stored at 10 RH 3 Devices require baking before mounting if any circumstance below occurs When the ambient temperature is 23 C 5 C and the humidity indication card shows t...

Page 47: ...is recommended to be 0 15mm For more details please refer to document 1 It is suggested that the peak reflow temperature is 235 245 C for SnAg3 0Cu0 5 alloy The absolute max reflow temperature is 260...

Page 48: ...The modules are stored inside a vacuum sealed bag which is ESD protected It should not be opened until the devices are ready to be soldered onto the application 7 3 1 Tape and Reel Packaging The reel...

Page 49: ...NB IoT Module Series BC95 Hardware Design BC95_Hardware_Design Confidential Released 48 51 PS 6 DETAIL A DETAIL A Figure 31 Reel Dimensions Quectel Confidential...

Page 50: ...mware_Upgrade_via_Universal_ Code_Loader_User_Guide BC95 Firmware Upgrade via Universal Code Loader User Guide 4 Quectel_RF_Layout_Application_Note RF Layout Application Note 5 Quectel_BC95_AT_Command...

Page 51: ...Restriction of Hazardous Substances RTC Real Time Clock RX Receive Direction USIM Universal Subscriber Identification Module SMS Short Message Service TAU Tracking Area Update TE Terminal Equipment TX...

Page 52: ...ILmin Minimum Input Low Level Voltage Value VImax Absolute Maximum Input Voltage Value VImin Absolute Minimum Input Voltage Value VOHmax Maximum Output High Level Voltage Value VOHmin Minimum Output H...