Digital Inputs
There are four general purpose digital inputs on GV600. They all are negative triggers.
Table 8.
Electrical Characteristics of the Digital Inputs
Logical Status
Electrical Characteristics
Active
0V to 0.8V
Inactive
Open loop
The following picture shows the recommended connection of a digital input.
Figure 7.
Typical Digital Input Connection
3.7.
Analogue Inputs
There is one analogue input on GV600WG, and the analogue input voltage range is from 0 to 32V.
The following picture shows the recommended connection.
Figure 8.
Typical Analogue Input Connection
Note:
Pin 6 is a multifunction pin: it can be configured as an analogue input.