QUBINO ZMNHCD1 Manual Download Page 1

 

Qubino 

 

        

The

 INNOVATIVE 

and 

SMALLEST

                

 

 

Flush Shutter 

 

ORDERING CODE 

Z-WAVE FREQUENCY 

ZMNHCD1 

868,4 MHz 

ZMNHCD2 

921,4 MHz 

ZMNHCD3 

908,4 MHz 

ZMNHCD4 

869,0 MHz 

ZMNHCD5 

916,0 MHz 

ZMNHCD8 

865,2 MHz 

This Z-Wave module is used to control the motor of blinds, 

rollers, shades, venetian blinds, etc … The module can be 

controlled either through a Z-Wave network or through the 

wall switch. 

Precise positioning is supported for motors equipped with 

mechanical or electronic end switches. The module is 

designed to be mounted inside a “flush mounting  box”, 

hidden behind a traditional wall switch. Module measures 

power consumption of motor  and support  connection of 

digital  temperature sensor.  It is designed to act as 

repeater in order to improve range and stability of Z-Wave 

network.

                      

 

Supported switches 

Module supports 

mono-stable

 switches (push button) and 

bi-stable

 switches

.   

Installation 

 

To prevent electrical shock and/or equipment damage, 

disconnect electrical power at the main fuse or circuit 

breaker before installation or any servicing.   

 

Make sure, that no voltage is present in the 

installation.   

 

Prevent the disconnecting device from being switched 

on accidentally. 

 

Connect the module according to electrical diagram.   

 

Locate the antenna far from metal elements (as far as 

possible).   

 

Do not shorten the antenna. 

Danger of electrocution!   

 

Module installation requires a great degree of skill and 

may be performed only by a qualified and licensed 

electrician. 

 

Even when the module is turned off, voltage may be 

present on its terminals. 

 

Note! 

Do not connect the module to loads exceeding 

recommended values. Connect the module only in 

accordance to the below diagrams. Improper connections 

may be dangerous. 

Electrical installation must be protected by directly 

associated over current protection fuse 4A, gG or Time 

lag T, rated breaking capacity 1500V (ESKA 522.723) 

must be used according to wiring diagram to achieve 

appropriate overload protection of the module

.

 The fuse 

must be installed in fuse holder type: Adels contact 503 Si/ 1 

DS.

 

Package contents 

 

Flush Shutter 

Electrical diagram 230VAC 

 

 

 

 

 

 

 

 

 

 

 

 

Notes for the diagram:

 

 

 
 
 

 

WARNING: Service button S 

must NOT  be used

  when 

module is connected to 110-230V power supply.

 

 

Durability  of the device depends on applied load. For 

resistive load (light bulbs, etc.) and 4A current consumption 

of each individual electrical device, the durability exceeds 

70.000 switches of each individual electrical device.   

Over-current protection 

When the current exceedes  4A, relay is automatically 

turned off and “Over-current detected” Notification is sent. 

To reactivate the module the power supply has to be turned 

off and on again. 

Module Inclusion (Adding to Z-Wave network) 

 

Connect module to power supply (with   

temperature sensor connected - if purchased), 

 

auto-inclusion (works for about 5 seconds after 

connected to power supply) or 

 

press push button I1 three times within 3s (3 times 

change switch state within 3 seconds) or 

 

press service button 

S

 (only applicable for 24 V SELV 

supply voltage) for more than 2 second. 

NOTE1: For auto-inclusion procedure, first set main 

controller into inclusion mode and then connect module to 

power supply. 

NOTE2: When connecting temperature sensor to module 

that has already been included, you have to exclude 

module first. Switch off power supply, connect the sensor 

and re-include the module

.

 

Module Exclusion/Reset (Removing from 
Z-Wave network) 

 

Connect module to power supply   

 

bring module within maximum 1 meter (3 feet) of the 

main controller, 

 

enable add/remove mode on main controller, 

 

press push button 

I1 

five times within  3s (5 times 

change switch state within 3 seconds) in the first 60 

seconds after the module is connected to the power 

supply or 

 

press service button 

S

 (only applicable for 24 V SELV 

supply voltage)    for more than 6 second. 

By this function all parameters of the module are set to 

default values and own ID is deleted. 

If push button I1 is pressed three times within 3s (or service 

button S is pressed more than 2 and less than 6 seconds) 

module is excluded, but configuration parameters are not 

set to default values.   

NOTE: If the module is included with parameters 71 with 

value different to default and module reset is done, wait at 

least 30s before next inclusion 

Associations 

Association enables Flush Shutter  module to transfer 

commands inside Z-Wave  network directly (without main 

controller) to other Z-Wave modules. 

Associated Groups

:   

Root device: 

Group 1: default reporting group (reserved for the main 

controller), 1 node allowed. 

Group 2: basic on/off (triggered at change of the input I1 

state and reflecting its state) up to 16 nodes. 

Group 3: basic on/off (triggered at change of the input I2 

state and reflecting its state) up to 16 nodes. 

Group 4: basic on/off (triggered at sensing moving direction 

of roller: up=FF, down=0) up to 16 nodes.

 

 

Group 5: basic on/off (triggered at reaching roller position: 

bottom=FF, top=0) up to 16 nodes. 

Group 6: basic on/off (triggered at reaching roller position: 

bottom=FF, not bottom=0) up to 16 nodes. 

Group 7: multilevel set (triggered at changes of value of the 

Flush Shutter position) up to 16 nodes. 

Group 8: multilevel set (triggered at changes of value of 

slats tilting position) up to 16 nodes. 

Group 9: multilevel sensor report (triggered at change of 

temperature sensor) up to 16 nodes. 

End point 1: 

Group 1: Lifeline group, 0 nodes allowed. 

Group 2: basic on/off (triggered at change of the input I1 

state and reflecting its state) up to 16 nodes. 

Group 3: basic on/off (triggered at change of the input I2 

state and reflecting its state) up to 16 nodes. 

Group 4: basic on/off (triggered at sensing moving direction 

of roller: up=FF, down=0) up to 16 nodes. 

Group 5: basic on/off (triggered at reaching roller position: 

bottom=FF, top=0) up to 16 nodes. 

Group 6: basic on/off (triggered at reaching roller position: 

bottom=FF, not bottom=0) up to 16 nodes. 

Group 7: multilevel set (triggered at changes of value of the 

Flush Shutter position) up to 16 nodes. 

End point 2: 

Group 1: Lifeline group, 0 nodes allowed. 

Group 2: multilevel set (triggered at changes of value of 

slats tilting position) up to 16 nodes. 

End point 3: 

Group 1: Lifeline group, 0 nodes allowed. 

Group 2: multilevel sensor report (triggered at change of 

temperature sensor) up to 16 nodes. 

Automatic calibration   

Automatic calibration is a process during which the Flush 

Shutter learns the position of the limit switches.   

Shutter positioning calibration 

(par. 71 set to 0) 

There are two procedures of calibration. 

Calibration through main controller UI 

1)    Include the module into the Z-Wave network, according 

to module include instructions. 

2)    Set the parameter 78 (Forced Flush Shutter calibration) 

value to 1. 

3)    Flush Shutter performs the calibration process, 

completing full cycle - up, down and up again. 

4)    Set the parameter 78 (Forced Flush Shutter calibration) 

value to 0. 

Calibration through the inputs I1 and I2 

1)    Include the module into the wireless network, 

according to module inclusion instructions.   

2)    Quick press the switch/push-button connected to I1 

input and wait until the Shutter reach upper limit switch. 

3)    Quick press the switch/push-button connected to I2 

input and wait until the Shutter reach lower limit switch. 

4)    Quick press the switch/push-button connected to I1 

input and wait until the Shutter reach upper limit switch. 

Slates tilting position calibration 

(par. 71 set to 1) 

When enabling venetian blind mode, position calibration for 

slats titling must be  done. After doing this, position and 

angle of slates can be set. By default full turn time for slates 

is set to 1,5s. This value can be changed with parameter 

72. 

1) 

Include and make module calibration according to 

section

 ‘

Shutter positioning calibration’. 

2) 

Set parameter 71 to 1 ‘Venetian blinds’. 

3) 

Exclude the module (without reset!)

4) 

Include the module

5) 

After module inclusion beside main Shutter  widget, 

another widget for slates control will appear on UI. 

6) 

By default full turn movement is set to 1,5s. If this time 

is too long (if after slates full cycle Shutter  starts 

moving up or down), decrease this time defined with 

parameter 72.

  If this time is to short (if slats will not 

turn for full cycle), increase this time defined with 

parameter 72.

 

Manual operation for Shutter   

(par. 71 set to 0) 

Module allows connecting of push-buttons (mono-stable) or 

switches (bi-stable) to I1 and I2 terminals. 

Clicking push-button (<2s) connected to I1 (up), initiates up 

movement. 

Clicking push-button (<2s) connected to I2 (down), initiates 

down movement.   

If the Shutter is moving, each click, of any push-button, will 

stop the movement.   

Keeping pressed push-button (>2s) connected to I1 (up), 

initiates up movement, until push-button is released. 

Keeping pressed push-button (>2s) connected to I2 (down), 

initiates down movement, until push-button is released. 

Manual operation for venetian blinds   

(par. 71 set to 1) 

Slates on start position - 0 degree 

Clicking push-button (for time < full turn slates time-par.72) 

connected to I1 (up), initiates slates turning towards end - 

180 degree position, until push-button is released. 

Clicking push-button (for time < full turn slates time-par.72) 

connected to I2 (down), initiates Shutter down movement. 

If the Shutter is moving, each click, of any push-button, will 

stop the movement.   

Keeping pressed push-button (for time > full turn slates 

time-par.72) connected to I1 (up), initiates full slates turn 

and up movement, until the push-button is released. 

Keeping pressed push-button (for time > full turn slates 

time-par.72) connected to I2 (down), initiates Shutter down 

movement, until the push-button is released. 

Keeping pressed push-button (for time > (full turn slates 

time +2s)) connected to I1 (up), initiates up movement, until 

push-button is released. 

Slates on end position - 180 degree 

Clicking push-button (for time < full turn slates time-par.72) 

connected to I1 (up), initiates Shutter up movement. 

Clicking push-button (for time < full turn slates time-par.72) 

connected to I2  (down), initiates slates turning towards 

start - 0 degree position, until the push-button is released. 

If the Shutter is moving, each click, of any push-button, will 

stop the movement.   

Keeping pressed push-button (for time > full turn slates 

time-par.72)  connected to I1 (up), initiates Shutter  up 

movement, until the push-button is released. 

Keeping pressed push-button (for time > full turn slates 

time-par.72) connected to I2 (down), initiates full slates turn 

and down movement, until the push-button is released. 

Keeping pressed push-button (for time > (full turn slates 

time +2s)) connected to I2 (down), initiates down 

movement, until push-button is released. 

Configuration parameters 

Parameter no. 10 -  Activate/deactivate functions ALL 

ON / ALL OFF   

Available config. parameters (data type is 2 Byte DEC): 

 

default value 255 

 

255 - ALL ON active, ALL OFF active. 

 

0 - ALL ON is not active ALL OFF is not active 

 

1 - ALL ON is not active ALL OFF active 

 

2 - ALL ON active ALL OFF is not active 

Flush  Shutter responds to commands ALL ON / ALL OFF 

that may be sent by the main controller  or by other 

controllers belonging to the system. 

Parameter no. 40 - Power reporting in Watts on power 

change for Q1 or Q2 

Set value means percentage, set value from 0 – 100 = 0% - 

100%. Available configuration parameters (data type is 1 

Neutral lead

 

Live lead

 

Q1 

Output for motor UP (open)

 

Q2 

Output for motor DOWN (close)

 

I2 

Input for switch/push button DOWN (close)

 

I1 

Input for switch/push button UP (open)

 

TS 

Terminal for digital temperature sensor (only for 

Flush  Shutter  module compatible digital 

temperature sensor, which must be ordered 

separately). 

Service button (used to add or 

remove module from the Z-Wave 

network in case of  24 V SELV 

power supply). 