EN
.
39
12.7.
Configuration Parameters
Parameter no. 1
–
Relay contact type
Defines the contact type when open/closed contact.
Values (size is 1-byte dec):
•
Default value 0
•
0 - NO (normally open) output type
•
1 - NC (normally close) output type
Parameter no 3.
–
turning off alarming
Values (size is 1-byte dec):
•
Default value 1
•
0
–
only by z-wave command (basic set, switch multilevel set, switch multilevel start/stop
level change, sound switch play tone, sound switch configuration, switch color set, switch
color start/stop level change, notification report idle)
•
1
–
capacitive input (up, down, left, right) or z-wave command (basic set, switch
multilevel set, switch multilevel start/stop level change, sound switch play tone, sound
switch configuration, switch color set, switch color start/stop level change, notification
report idle)
Parameter no. 10.
–
auto on timer
Defines the time after which the device is turned to last known state.
Values (size is 1-byte dec):
•
Default value 0
•
0
–
disabled
•
30
–
32535 = 30
–
32535 seconds after which the device turns on
Parameter no. 11.
–
auto off timer
Values (size is 2-byte dec):
Defines the time after which the device is turned to last known state.
•
Default value 0
•
0
–
disabled
•
30
–
32535 = 30
–
32535 seconds after which the device turns off