CenterPunch Lighting Effects Server Owner's Manual
P/N: 400275000; Rev. F, 03/22
7
1.4.4
Connect the system
FOR BOWLAND / BOWLAND-X CENTERS ONLY:
Install the supplied network switch on the rear of the curtain
wall, in the middle of the lanes (for example between lanes 4 and 5 in an eight lanes center). We will call it
MAIN Scoring Network switch. Connect the second network card of the Conqueror X/Pro Server computer to
the MAIN Scoring Network switch, using the 250 ft. (75 m) network cable.
1.4.4.1
Connection in the case of EDGE String equipped with SYSTEM CONTROLLER, ES
P/N: 051-200-90X-YY
Connect the “N1 NETWORK” plug of the
Effect Server X to the MAIN Scoring Network switch.
Connect the “D1 DMX COM LINE” to the “DMX 1 IN/OUT” of the first SYSTEM CONTROLLER, ES unit for the
DECK LIGHTING
.
Connect the “D
2
DMX COM LINE” to the first DMX Dimme
r unit of the
CAPPING LIGHTING
.
Connect the DMX 120 Ohm terminator to the “D2 DMX IN/OUT” connector of the
last SYSTEM CONTROLLER,
ES unit and/or the last DMX Dimmer 2 unit.
Power on the CenterPunch Lighting Effects Server: connect the power cable to the Effect Server X and plug
it into an electrical outlet.