QS-CH2
2.7.
POWER REQUIREMENTS
Power Cabinet (QS-SB2) contains the power supply for connected actuators. If there
is no certainty if fuses or entire electrical installation can handle QS-CH2 , contact a
qualified electrician.
Converter specification
Breaker
specification
Power consumption
Average Power
[kVA]
Peak Power
[kVA]
Peak Current
[A]
Average Power
(stress test)
[kW]
Average Power
(typical game)
[kW]
120 V power supply
1
1,5
12,4
0,7
0,06
230 V power supply
1
1,7
7,4
0,6
0,06
*With heavy payload and /or intensive simulation, average power consumption may rise.
WARNING
Always
UNWIND THE CABLE COMPLETELY
when using a cable reel and untangle an
extension cord before connecting the device to the power supply.
WARNING
Check if the power cord plug has grounding connection (with 3 pins). In order
to reduce risk of electric shock
DO NOT
use plug without grounding connection
(without center pin).