1- INTRODUCTION
Congratulations! You are now owner of a QUATRO purifier, an advanced effective purifier, designed specifically for the human respiratory system. You can expect
a noticeable improvement in air quality as the unit begins the process of reducing microscopic airborne particulate, dust, harmful gases, smoke, pollen etc.
2- SAFETY PRECAUTION
Read all of the instructions contained within this manual before operating this unit. Keep this manual, as it contains information for proper operation and
maintenance. Keep all fastening hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which filters are installed &
replaced. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong
adapters to defeat proper grounding. If servicing the unit, be careful not to touch the motor as soon as it has been turned off. It is hot and can cause injury.
Do
not substitute any other filters odor granules.
3- ALWAYS UNPLUG FROM SUPPLY BEFORE DOING ANY MAINTENANCE OR FILTER SERVICE
Upon arrival, inspect unit for either visible or concealed damage. Damage should be immediately reported to the transport company.
4- PRE START-UP CHECKLIST
a)
All filters are present and are correctly installed prior use;
b)
Labels and serial numbers are present for future identification;
c)
Verify that power supply is compatible with equipment. Check the unit is plugged into a grounded receptacle;
d)
The casters (wheels) must be secure in place prior the moving the air purifier.
5- START-UP
a) Place the air purifier in the desired area for use. Ensure all filters are installed;
b) Make sure the air intake area (bottom) is not obstructed in any way.
c) Insert male end of power cord into grounded circuit;
d) Turn power toggle switch to "HIGH" position.
e) Air purifier should now be functioning and operational;
WARNING: DO NOT OPERATE UNIT UNLESS ALL FILTERS ARE IN PLACE.
6- OPERATION
Unit is designed to remove light odor (B301) and dust particles (large & small) that are suspended in the air. Particles will enter the unit at the top, and clean fresh
air exits at the bottom. This unit is designed to operate 24 hours per day, 7-days a week. The unit must operated at its highest speed for optimum performance.
Quatro’s “FILTER ALERT” Warning System will advise you when the unit is not operating at its peak efficiency, and maintenance must be performed. When the
filter is spent, light on the Control Panel will illuminate, advising you to replace filter.
7- FILTER MAINTENACE
Bio-Scan
(
B301
-Odor & HEPA Air Purification)
Bio-Scan
(
B300
-HEPA Air Purification)
Part No.:
Stage #
Filter Type
Repl. Intreval
Part No.:
Stage #
Filter Type
Repl. Intreval
F071(6/bx)
Stage I
Dust Filter
Every 6 months
F073 (2/bx)
Stage I
Dust Filter
Every 12 months
Nc-gpc
Stage II
Odor Granule refill
When odor is detected
F075
Stage II
Hepa Filter
24 months
F075
Stage III
Hepa Filter
24 months
7- SPECIFICATIONS
Dimensions, Height:
26.25”(667mm)
Voltage / Current
120/1/60 / 1.0amps
Dimensions, Width: *
12.75” (324mm)
Max. Power Consumption:
85watts
Dimensions Length:
15.75” (400mm)
Approx. Weight:
48lbs (22kgs)