Rack-Mount RDMS
TM
Telemetry Receiver
27
Quasonix, Inc.
4.1.4.6
Setting Data Polarity
The Data option on the Main Menu is for adjusting the data polarity. The parameter options are Normal and
Inverted. To change the polarity, press the Enter key when the parameter is highlighted from the Main Menu. The
default is Normal.
Figure 31: Main Menu, Data Setting
4.1.4.7
Setting Clock Polarity
The Clock option on the Main Menu is for adjusting the clock polarity. The parameter options are Normal and
Inverted. To change the polarity, press the Enter key on the front panel keypad when the parameter is highlighted on
the Main Menu. The default is Normal.
Figure 32: Main Menu, Clock Setting
4.1.4.8
Derandomizer State
The RM RDMS™ includes a derandomizer, which can be enabled (On) or disabled (Off) by selecting the parameter
from the Main Menu and pressing the Enter key on the front panel keypad. The default setting for the derandomizer
is Off.