Rack-Mount RDMS
TM
Telemetry Receiver
90
Quasonix, Inc.
If the Frequency Diversity On box is checked, the settings are automatically copied to both channels.
Note:
Whenever the Diversity Combiner is On, any changes made to the Basic Settings: Frequency option (even
with Frequency Diversity On enabled) causes Modulation Scaling for both channels to be set to Tracking.
4.2.3.1.1.7 Copy Channel Settings
There may be instances where the operator does not want to use the diversity combiner but still wants to have any
changes made to given channel copied to the other channel. Copy Channel Settings allows the user to select the
channels to copy.
Click on the Copy Enabled checkbox to allow channel copying, then select additional copy settings.
If the CH1 => CH2 option is selected, then any settings made for channel 1 will be copied to channel 2 but channel
2 settings will not copy to channel 1.
The reverse is true if the operator selects the CH1 <= CH2 option.
After selecting the desired copy option, click on the Copy All screen button to complete the copy action.
Note:
If the diversity combiner is On, the copy channel settings are ignored.
Figure 161: Copy Channel Settings
4.2.3.1.2 Advanced Settings Tab
The Advanced Settings tab displays in two different formats: one format when the modulation is set to PCM/FM and
a second format for all other modulation settings.
When the modulation is set to PCM/FM. the Advanced Settings tab provides the user with:
•
Modulation Scale Settings
•
AGC and AM settings for antenna tracking
•
Tape Output Settings
•
Muting Settings
•
Synchronize Bit Rate Settings
•
Video Settings
•
Encoding selections
•
Four Enable/Disable checkbox options: Bi-Phase, Convolutional Decoder, Spectrum Inversion, and DC
Antenna