Quasar CF-3211-00 Quick Installation Manual Download Page 1

CF-3211/4221/4251 QIG_March17_2014 

 

 

 

 

 

Quasar CF-3211/CF-4221/CF-4251 Series Fixed Camera Quick Installation Guide

 

Initial Configuration 

1.

 

Prepare the camera: 

a.

 

Remove the camera’s protective packaging. 

2.

 

Lens Mounting: 

a.

 

Remove the plastic insert covering the threaded camera lens-mount. 

 

TIP

:  Do not touch the sensor or allow dust to accumulate in the lens mount. 

b.

 

If you are using a C-mount lens, screw a 5mm adapter ring into the C-Mount to convert it to a CS-Mount. See figures below. 

 

 

C to CS Mount Adapter

 

Assembled Adapter

 

 

c.

 

Align the lens threads into the lens mount and screw in the lens. 

d.

 

If your lens has a DC auto iris, plug the auto iris cable from the lens assembly into the AUTO IRIS control port of the camera. 

3.

 

Attach an Ethernet cable: 

a.

 

Connect one end of a Cat 5 Ethernet cable to the Ethernet port on the side of the camera, and the other end  to a Power 
Sourcing Equipment (PSE) device, such as a PoE switch.  

b.

 

Verify that the LED on the port is green, indicating a good network connection. A yellow LED flashes when there is network 
activity.  

NOTE:

 The camera IP Address and the subnet mask IP Address are automatically supplied by the DHCP server.  If the DHCP server is not 

available, the camera’s default IP address is 192.168.0.250. 

TIP:

 A camera setup adapter, such as Veracity Pinpoint, can be used to connect a laptop directly to the camera using PoE. 

NOTE

: If your computer’s OS is IE 9, work in Compatibility Mode. 

4.

 

Set the camera’s IP address: 

a.

 

Open the DNA application. Select the unit requiring IP assignment. See figure below. 

b.

 

Right-click the mouse and select the unit or press the Assign IP 

button to open the DNA 

Assign IP

 screen. 

 

c.

 

If your network does not have a DHCP server, enter the IP Address, Mask (Netmask) and Gateway values in the dialog box 
displayed below. 

d.

 

Click 

Update

 and wait for 

OK

 status 

to be displayed. The IP value has been assigned. 

 

5.

 

Disconnect the cable: 

a.

 

Disconnect the Ethernet cable. 

b.

 

If you are using a power supply, turn it off and disconnect it. The camera is ready for mounting in a site installation. 

c.

 

Refer to the camera’s user manual for mounting instructions. 

Site Installation 

WARNING:

 The Quasar CF-3211/CF-4221/CF-4251 fixed camera must be kept in a clean and dry indoor environment or in the protective 

outdoor mounting kit supplied with the outdoor model. Operating temperature should be maintained within -10°C ~ 50°C (14° ~ 122°F). 
Operating humidity should be between 10-90% (non-condensing). The camera should be kept dry, free from water condensation, dust, 
dirt, and smoke.  

1.

 

Mounting the camera: 

 
Indoor Installations (no housing) 

a.

 

Install the camera in the ceiling, wall, or on a flat surface. A security camera wall-mount bracket stand, sturdy enough to 
hold the camera in a fixed position for the field of view, is required. 

b.

 

Screw the bracket or stand to the mounting socket on the top of the camera. 

 
Indoor/Outdoor Installations (using a typical protective camera housing) 

For outdoor installation, the camera must be installed in a protective 
housing such as a DVTEL CF-X201-00 camera housing. Refer to the housing 
manufacturer’s installation instructions. 

 

2.

 

Attach cables: 

Thread cables through opening at the side of the camera:  

a.

 

Plug the Cat 5 cable into the camera’s Ethernet port. 

b.

 

Plug the other end of the cable into an IEEE 802.3at PoE switch. 

       

NOTE: 

Connection to a 24VAC or 12VDC power supply is optional. 

c.

 

If applicable, connect the Alarm In, Alarm Out, Audio In and Audio Out terminal blocks to external devices.  

d.

 

Connect the other end of the Cat 5 cable to the network. 

Connecting the cables and wiring to the Camera 

The Camera Connection Panel contains all of the input and output terminal blocks required for standard operation. 
 

 

 

                  