background image

PM9112C Revision 1

Product Manual

Model 9112

Communication Bridge

Data Control Projects

Quartech Corporation

159

2

3 Angelo Drive

Macomb Township, Michigan 48042-4050

Phone:  (586) 781-0373   FAX: (586) 781-0378

   www.QuartechCorp.com

PM9112C Revision 1

The product described in this document can have a variety of uses, the user and those responsible for applying this
equipment must satisfy themselves as to the acceptability of each application and the use of the unit.  Under no
circumstances will QUARTECH CORPORATION be responsible or liable for any damage, including indirect or
consequential losses resulting from the use, misuse, or application of the unit.

The text, illustrations, charts, and examples included in this document are intended solely to help explain applications
of the product.  Due to the many variables associated with specific uses or applications, QUARTECH CORPORATION
cannot assume responsibility or liability for actual use based upon the data provided in this document.

No patent liability is assumed by QUARTECH CORPORATION with respect to the use of circuits, information,
equipment, or software described in this document.

This document is subject to change without notice.

Summary of Contents for 9112

Page 1: ...RTECH CORPORATION be responsible or liable for any damage including indirect or consequential losses resulting from the use misuse or application of the unit The text illustrations charts and examples...

Page 2: ...tive RAM Files 6 Logic Block Editor 7 Processing Logic Blocks 7 Function Block Editor 9 Section 3 Download 9112 Configuration 11 Section 4 Download Project File 12 Section 5 Status Indicators 13 Appen...

Page 3: ...s data between various devices but also has the ability to internally store data and perform advanced operations on data The movement and manipulation of data is decision based using logic block that...

Page 4: ...oject File can be downloaded To create a new project choose File New Project from the menu bar The dialog window below will open Enter a project name up to eight characters then assign device drivers...

Page 5: ...r A project is a collection of files within a file folder or directory The file folder or directory name is the project name The project files are automatically created and maintained by ProjectMaker...

Page 6: ...the Database Editor Within a Driver Database the designation entered into the Address field must conform to a specific syntax This is usually synonymous with the syntax used by the programming softwa...

Page 7: ...o it This is done automatically based on the data stored in the element Typically a numeric value will use four bytes of data while a string may require the fill 128 bytes When the 9112 is first power...

Page 8: ...resources are read only The clock and calendar resources are available only if the Clock Calendar Memory option is installed in the 9112 hardware Retentive RAM Files The Retentive RAM File allow initi...

Page 9: ...at were assigned within the Retentive RAM Database Editor and can not be changed in this list The values entered can be signed or unsigned long integers single precision floating point or ASCII text s...

Page 10: ...e available function elements Left click the drop down list box to select a particular group of function elements Use the scroll bar to find the desired function element then left click to drag and dr...

Page 11: ...p menu Here is a typical Function Block Editor Label The Label field allows a string of up to ten characters long to be assigned to the Function Block The label is displayed above the Function Block w...

Page 12: ...is an equal sign then the address remains unchanged Left click on the icon to toggle between options To explain how the multiple iteration feature works a simple addition function will be used D A B...

Page 13: ...enable configuration mode 2 Apply power to the 9112 To open the 9112 configuration screen left click the desired project name to highlight it then from the menu bar select Communication Configure 9112...

Page 14: ...wer to the 9112 To open the 9112 project download screen select Communication Download to 9112 4 Go Online to establish a connection with the 9112 and read its current configuration This will establis...

Page 15: ...Green Port 2 Receiving data Flash Green Off Off No serial communication Minor Faults A minor fault is certainly cause for concern and action must be taken to eliminate the source of the fault however...

Page 16: ...instructs otherwise Switch 3 Port 1 Termination This switch is set to the on position when Port 1 is configured for RS 485 communication and line termination is required Switch 4 Port 2 Termination Th...

Page 17: ...other conductive particles such as wire clippings from entering the unit during installation Failure to protect the unit may cause damage when power is applied and may void the warranty A minimum cle...

Page 18: ...ch Corporation web site Also available is the latest version of this product manual plus other related manuals and documents Quartech Corporation 15943 Angelo Drive Macomb Township Michigan 48042 4050...