QUARTA RADEX RD1212 User Manual Download Page 11

Setting of recording period

1. Select 

menu   monitoring

.

2. Move   to

 

recording period

 and press  .

3. By moving   select 

recording period

 

and press  , a 

tick   symbol will appear next to the selected value.

Audible alarm

Selecting this function allows the audible alarm to respond 

to registration of a quantum.

In case a threshold function is ON, the audible alarm is 

issued only when registered value exceeds the threshold 

level.

Switching ON 

audible alarm

1. Select 

menu

   

setup

.

2. Move   to 

audio

 and press  , a tick   symbol will 

appear next to item 

audio

.

Switching OFF 

audible alarm

1. Select 

menu

   

setup

.

2. Move   to 

audio

 and press  , a tick   symbol next 

to item 

audio

 will disappear.

Vibration Signal

Turning ON this function allows the vibration signal to 

respond to registration of a quantum.

In case a threshold function is turned ON, the vibration signal 

is issued when registered value exceeds the threshold level.

Switching ON 

vibration alarm

1. Select 

menu

   

setup

.

2. Move   to 

vibra-call

 and press  , a tick   symbol 

will appear next to 

vibra-call

.

Switching OFF 

vibration alarm

1. Select 

menu

   

setup

.

2. Move   to 

vibra-call

 and press  , a tick   symbol 

next to item 

vibra-call

 will disappear.

Backlight

This function activates backlight of the display for 

7 seconds, when any key is pressed.

Turning ON 

backlight

 function

1. Select 

menu

   

setup

.

2. Move   to 

backlight

 and press  , a tick   symbol 

will appear next to 

backlight

.

Turning OFF 

backlight

 function

1. Select 

menu

   

setup

.

2. Move   to 

backlight

 and press  , a tick   symbol 

next to 

backlight

 will disappear.

RADEX RD1212

Device appearance

Device operation

Miscellaneous

RADEX RD1212

User Guide

8

Summary of Contents for RADEX RD1212

Page 1: ...Radiation Detector RADEX RD1212 User Guide ...

Page 2: ...ures radioactivity stores measurement results in memory data transfer to PC self testing Time and Date functions audible alarm vibration alarm integrated flashlight multilingual Eng De Fr Rus Jp RADEX RD1212 User Guide Please note that this device uses statistical probability function to calculate radiation values Even in identical circumstances two identical devices may show varying results The r...

Page 3: ...f RadexRead software 5 Operation of RadexRead software 5 Settings Threshold 7 Data collection 7 Audible alarm 8 Vibration alarm 8 Backlight 8 Time and Date 9 Language 9 Flashlight 9 Miscellaneous Technical specification 9 Recommendations on surveying of objects 10 Operational restrictions 10 Symbols used in this Guide selection indicator function is Selected sequence of actions note Device operati...

Page 4: ...DEVICE APPEARANCE Device operation Setup Miscellaneous RADEX RD1212 User Guide 1 Location of sensor Battery compartment lid Flashlight Key Mini USB Display Key Key ...

Page 5: ...tion On Off 4 Backlight 5 Key function 6 Key function 7 Measurement result 8 Key function 9 Date 10 Time 11 Background Radiation value 12 Alarm threshold 13 Battery charge indicator high low battery should be replaced 14 Unit of measurement micro Sievert per hour 15 Blinking indicated detection of a quantum 16 Indicator of the number of measurement cycles 1 cycle 10 cycles and more ...

Page 6: ...on Menu from the Main screen press The Main Menu will be displayed use buttons and to scroll the cursor next to desired function Use button to Select move the cursor to the desired function and Select it by pressing A tick mark will Appear Disappear next to the desired function After 30 seconds of inactivity the device will revert to Main Screen Please remove the batteries if the device is not goi...

Page 7: ...ation was measured earlier you may proceed with measuring current radiation in excess of background 1 Enter menu background 2 Move to on position and press DEVICE OPERATION Measurements Measurement begins when the device is turned On The first result will appear on display after 10 seconds Measurements with Background Function While taking measurements with Background Function two radiation values...

Page 8: ...lect Install RadexRead 3 Follow the prompts of the installation Wizard to install RadexRead application Operation with RadexRead program RadexRead allows you to perform the following functions view measurement results stored in memory save results in TXT and CSV formats delete measurement results from the device memory Connecting the device to PC 1 Turn On the device 2 Connect the device to PC usi...

Page 9: ...Start RadexRead program 2 Select SAVE a dialog box will open 3 Select path to save the file 4 Enter filename 5 Select a file format in which the measurement results will be stored 6 Click SAVE Deleting data from PC memory 1 Start RadexRead program 2 click DELETE Device appearance Setup Miscellaneous RADEX RD1212 User Guide 6 ...

Page 10: ...2 User Guide 7 SETUP Threshold This function allows to set dose power level value which will trigger an alarm Audible or Vibration Turning ON Alarm function 1 Select menu levels 2 Move to on position and press Turning OFF Alarm function 1 Select menu levels 2 Move to off position and press Setting threshold level to trigger an alarm 1 Select menu levels 2 Move to a numerical value and press 3 By p...

Page 11: ... function allows the vibration signal to respond to registration of a quantum In case a threshold function is turned ON the vibration signal is issued when registered value exceeds the threshold level Switching ON vibration alarm 1 Select menu setup 2 Move to vibra call and press a tick symbol will appear next to vibra call Switching OFF vibration alarm 1 Select menu setup 2 Move to vibra call and...

Page 12: ...gs Threshold 0 30 µSv h Audible alarm on Date collection off Vibration signal off Backlight off Device appearance Device operation Setup RADEX RD1212 User Guide 9 Time and date Setting TIME 1 Select menu setup time and date 2 Move to the first line time and press 3 Use or to set hours and press 4 Use or to set minutes and press Setting DATE 1 Select menu setup time and date 2 Move to the second li...

Page 13: ... the open site near the surveyed building in 5 locations 2 Perform measurements inside the building 3 If the registered radiation inside a building exceeds radiation at the open site by more than 0 2 mSv h this may indicate presence of unfavourable radiation environment Device appearance Device operation Setup RADEX RD1212 User Guide 10 OPERATIONAL RESTRICTIONS Do not subject the device to high te...

Reviews: