background image

7.  WiFi Ad

-

hoc connection

 

On your device (phone, laptop etc.): 

 

15 seconds after the A034 has powered up, you 
can scan for a WiFi network with an SSID similar to 

QK

-

A034xxxx

’. 

Connect to 

QK

-

A034xxxx

’ 

with 

the default password: 

88888888

’. 

 

 

Chart software: 

in your chart software, set the 

protocol to 

TCP

’, 

IP address to 

192.168.1.100

’ 

and port number to 

2000

’ 

 

For Station mode WiFi setup, use the Configura-
tion software. (see below)

 

Disclaimer: 

This product is designed to aid navigation and should be used to augment normal navigational 

procedures and practices. It is the user

s responsibility to use this product prudently. Neither Quark

-

elec, nor 

their distributors or dealers accept responsibility or liability either to the product user or their estate for any 
accident, loss, injury or damage whatsoever arising out of the use or of liability to use this product.

 

Email: 

info@quark

-

elec.com

 

 

V1.0(12/19)

 

QK

-

A034

 

Note: 

SeaTalk

™ 

is a registered trademark of Raymarine.

 

USING THE CONFIGURATION SOFTWARE (WINDOWS):

 

WiFi can be changed from Ad

-

hoc (default) to  Station mode or Standby.

 

Station mode 

is configured by inputting your router/access point

s details into the Configuration 

software.  (once configured, the correct settings must be entered into your chart software.)

 

 

Filtering: using the black list function

 

If desired, selected NMEA sentences can be blocked  from chosen input/s, using the 

black list 

‘ 

field. Remove the 

‘$’ 

or 

‘!’ 

from the 5 digit NMEA talker and sentence identifier and insert sepa-

rated by commas. For example to block 

‘!

AIVDM

’ 

and 

‘$

GPAAM

’ 

enter 

AIVDM,GPAAM

’ .

 

Up to 8 sentences types can be filtered from each input port.  If blacklisting SeaTalk  data, block 
the corresponding NMEA message (see the manual for a full list of converted messages).

 

 

Monitor the  data stream Via USB

 

Operator can use the display tab on the operation tool to monitor all the data send from NMEA 
inputs, SeaTalk input to NMEA 2000 network together with all the data were send through NMEA 
2000 backbone (PCDIN and NMEA 0183 format)

 

 

NMEA Baud rates: 

Default Baud rates are set to:

 

• 

NMEA IN 1 and 2: 4800bps

 

• 

NMEA IN 3: 38400bps 

 

These can be changed as required.

 

 

Set

-

Up guide

 

QK

-

A034

 

NMEA 0183 x3 & SEATALK

™ 

TO 2000 CONVERTER

 

WITH WIFI/USB OUTPUT

 

All products are CE, RoHS certified

 

More information at www.quark

-

elec.com

 