Chapter 3 Changing the Library Configuration
Changing the Baud Rate Setting
Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide
67
Changing the Baud Rate Setting
3
The
Baud Rate
option controls the baud rate setting of the serial
diagnostics port. You can set the baud rate to any standard rate
between 1200 baud and 38400 baud.
To set the
Baud Rate
:
1
Access the
Configuration
screen (see
2
Press the
Up
or
Down
buttons until
Baud Rate
is highlighted.
3
Press
Select
.
4
Use the
Up
or
Down
buttons to select the desired
Baud Rate
setting. The available settings are
38400
,
19200
,
9600
,
4800
,
2400
, and
1200
.
5
Press
Select
.
To return to the
Configuration
screen without changing the
option setting, press
Cancel
.
6
Press
Main
to return to the main screen.
Setting the Time
3
To set the time:
1
Access the
Configuration
screen (see
2
Press the
Up
or
Down
buttons until
Time
is highlighted.
3
Press
Select
.
Caution:
If you do not return to the main screen after
changing this setting, your change will not be
saved to NVRAM.