Scalar i2000 Installation Guide
269
Adding a 24-Slot I/E Station to an Expansion Module
This section describes how to upgrade an expansion module to include a 24-slot I/E station.
Required tools: #2 Phillips screwdriver, 2.5 mm hex wrench, disposable screw capture tool, wire cutters (for
plastic ties), ESD strap
1
You must export all media from the access door being upgraded.
a. Log into the Library Management Console (LMC).
b. Click
Operations
→
Export.
2
Before removing any magazines in the access door of the expansion module you are upgrading,
determine if the magazines are used in any partitions.
3
If the
Automatic Teach
mode is being used, disable it to perform this upgrade procedure.
4
Remove the magazines in the access door from each partition(s) using the following procedure:
a. Click
Physical
on the
View
menu.
b. Click
Setup
→
Partitions
→
Configure.
The
Partitions
dialog box is displayed.
c. Select the partition that include the affected magazines and click
Modify.
d. Return the affected magazines to the physical pool.
e. Repeat Steps a through d for each partition associated with the access door you are upgrading.
5
Shut down the library.
For more information, see
Note
You can add 24-slot I/E stations to the control module and any of the first seven
expansion modules.
Summary of Contents for Scalar i6000
Page 20: ...8 About This Guide and Your Product...
Page 38: ...26 Installing a Stand Alone Control Module...
Page 104: ...92 Installing a Multi Module Library...
Page 156: ...144 Installing Cartridges...
Page 164: ...152 Setting up Your Library for Access...
Page 242: ...230 Configuring the Library...
Page 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Page 318: ...306 Adding Optional Hardware...
Page 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Page 356: ...344 Testing and Calibrating the Digital Level...
Page 362: ...350 LBX Board and Terminator...
Page 380: ...368 Glossary...
Page 384: ...372 Index...