Quantum QC Series Quick Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

 

  Missing Parts, contact Pach and Company 1-888-678-7224 

  Defective system under manufacturer warranty,  

call 1-888-678-7224 for advance replacement 

 

24 Months warranty

 for complete system 

 

6 Months warranty

 for Printed Circuit Board  

Manuals are available online at www.pach-co.com

 

Exit program, cancel call 

23 

Lock-out Count 

 

Save program 

24 

Alarm 
0= disable 
1= local beep for 60 
seconds 
2= disable system for 60 
seconds with no beep 
3= call directory (0-9) 

00 

Change master code (0000 is 
default) 

25 

Keypad beep 
0= disable (default) 
1=enable 

01 

Add new  forwarding tenant’s 
directory 

26 

Door beep 
0= disable 
1= enable (default) 

02 

Edit existing tenant’s directory 

27 

Talk time (060-240 
second). Default=60 
second 

03 

Delete existing tenant’s 
directory 

28 

Unlock relay1 time  
(12-99 second). Default= 
12 second 

04 

Clear all forwarding tenant’s 
directory 

29 

Unlock relay2 time  
(12-99 second). Default= 
12 second 

05 

Enable/Disable Call 

33 

Temporary code 

06 

New access code 

34 

Special code 

07 

Delete access code 

35 

Temporary card 

08 

Clear all access code 

36 

Special card 

09 

Access code digit (4-8 digit). 
Default is 4-digit 

38 

System acknowledge  
(0-9). Default= 3 

10  

Add new card 

39 

Remote access 
0= disable 
1=enable (default) 

11 

Delete card 

40 

DTMF relay 1 (0-9). 
Default=9 

12 

Clear all card 

41 

DTMF relay 2 (0-9). 
Default=8 

13 

Set time 

42 

Relay 2 Mode 
1= door control (default) 
2= relay 2 trigger 
simultaneously as relay 1 
3= enable if function code 
24 is enable 
4= turn relay 2 on and off 
On=7, Off=6 

14 

Set date 

43 

DND: do not disturb time 
zone (0-9) 

15 

Initializing event recording 

44 

Disable Time zone relay 
1, 2 or both 

16 

AUS= auto unlock schedule 
(0-9 schedule) 

45 

Relay 1 and 2 unlock 
timer 

17 

TMZ= time zone. 20 TMZ, 00-
20. 

46 

Firmware version 

18 

HLD= holiday zone. 20 HLD, 
1-20 

48  

PBX enable. Default= 
disable 

19 

Directory digit (2-4 digit). 
Default is 2-digit 

49  

Edit Access code 

20 

AUXIN1 
0= disable (default) 
1= enable control by relay 1 
open interval 
2= relay 1 control by AUXIN1 

50 

Erase the memory to 
factory default 

21 

AUXIN2 
0= disable (default) 
1= enable control by relay 2 
open interval 
2= relay 2 control by AUXIN2 

51 

Welcome screen 

22 

Do not disturb 
0= disable (default), 1= enable 

 

 

Log on to programming:

 Press  

 

and

 simultaneously then release, 

the welcome message will stop 
scrolling (repeat if screen still scrolls) 
enter 4-digit “

MASTER CODE

” (0000 

is default), the screen will show: 

 

Select the “

Function Code

” from the 

table 

OPERATION 

Opening the door  remotely

 press 

 (relay 1) or 

 (relay 2) 

Opening the door  with the access code

 press 

 (display 

screen will stop scrolling) then press a valid 4-digit access code. 

Extending talk time

 tenant must press 

 from the phone after 

the time out warning beep. 
 

Calling into the system

:  

1.  Enable function code 39 and function code 38 must be set 1-9 
2.  Call the system phone number, hear one beep if the system 

answering the call. 

3.  Press 

 then 4-digit master code, hear one short beep 

4.  Press 

 to establish two way communication 

5. Press 

or to release the door.

 

OPERATION 

Two ways call  from the system 

1.  Press 

 to scroll name from A-Z or 

 to scroll name from Z-A 

then press 

 to call name selected. 

2.  Press 

 wait for dial tone then press the directory number 

QC1

IP

 and QC2

IP

 DEFAULT IP 

IP: 192.168.1.230 
SUBNET: 255.255.255.0 
GATEWAY: 192.168.1.1 
DNS: 192.168.1.1  
USERNAME: Administrator 
PASSWORD: 8888    

WARNING:

DO NOT USE ON BOARD 

12VDC and GND TO POWER A DOOR 
STRIKE OR MAGNETIC LOCK 
 
SEPARATE POWER MUST BE USED TO 
POWER A DOOR STRIKE OR MAGNETIC 
LOCK. 

 