Quantum Q5VOIP Series Programming Manual Download Page 2

Q5VOIP SERIES MANUAL

file:///C|/PACH-CO.COM-2022-B/online_manual/q5voip_manual.htm[4/27/2022 8:54:09 AM]

Function Code 02: Edit Existing Directory
Function Code 03: Delete Tenant Directory
Function Code 04: Clear All Tenant Directories
Function Code 05: Enable or disable Call 
Function Code 06: Add New Access Code
Function Code 07: Delete Access Code
Function Code 08: Clear All Access Codes
Function Code 09: Access Code Digit
Function Code 10: Add Card
Function Code 11: Delete Card
Function Code 12: Clear All Cards
Function Code 13: Set Time
Function Code 14: Set Date
Function Code 15: Initializing Event Recording
Function Code 16: Auto Unlock Schedule (AUS)
Function Code 17: Time Zone (TMZ)
Function Code 18: Holiday Zone (HLD)
Function Code 19: Directory Digit
Function Code 20: AUXIN1
Function Code 21: AUXIN2
Function Code 22: Do Not Disturb

Function Code 43: Do Not Disturb Zone
Function Code 44: Disable Time Zone Relay
Function Code 45: Relay 1 and 2 Unlock Timer
Function Code 46: Firmware Version
Function Code 48: PBX Enable
Function Code 49: Edit Existing Access Code,
Temporary Code and Special Code
Function 50: Erase Memory to Factory Default
Function Code 51: Welcome Screen

CHAPTER 5 OPERATIONS

Call from the System
Opening Door Remotely
Opening Door Using Access Code, Temporary Code
and Special Code
Opening Door Using Card, Temporary Card, and
Special Card
Extending Talk Time
Call the System from Remote Location

CHAPTER 6 QWCM

LIMITATIONS OF LIABILITY

This manual is subject to change without notice.

Pach and Company is not liable for any errors that might occur from use of this document, nor is any commitment to
update the information herein implied.

Pach and Company does not assume any liability for any damages, which may arise in installation or use of the Quantum
Q5VOIP Series  Pach and Company does not assume liability for any incompatibility between the Quantum Q5VOIP
Series and users devices.

Pach & Company reserves the right to make changes without prior notice to any products in order to improve reliability,
function or design.

 

PRODUCTS LIMITED WARRANTY

If your product does not work properly because of a defect in materials or workmanship, Pach and Company (referred to
as the warrantor) will, for the length of the period indicated on the chart below, which starts with the date of original
purchase (Limited Warranty Period), at its option either (a) repair your product with new or refurbished parts or (b)
advance replacement with new or refurbished product. The decision to repair or advance replacement will be made by the
warrantor. Advance replacement will be ship UPS ground under the warranty period with no charge. 

The defective product

must be return to Pach and Company within 15 days after receiving the advanced replacement otherwise you will be
billed the full amount.

Summary of Contents for Q5VOIP Series

Page 1: ...e Function Code 01 Add New Tenant Directory Function Code 23 Lock out Count Function Code 24 Alarm Function Code 25 Keypad Beep Function Code26 Door Beep Function Code 27 Talk Time Function Code 28 Un...

Page 2: ...Opening Door Using Card Temporary Card and Special Card Extending Talk Time Call the System from Remote Location CHAPTER 6 QWCM LIMITATIONS OF LIABILITY This manual is subject to change without notic...

Page 3: ...LISTED UNDER LIMITED WARRANTY COVERAGE THE WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR RISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY...

Page 4: ...nt 10 F 140 F Relative Humidity 0 95 non condensing Double 3 4 knocks out on the back and bottom panel Features Web Based programming Event recording Automatic Enrollment 10 tenants 100 cards 100 acce...

Page 5: ...t input device such exit switch postal lock etc 8 DOORS1 DOORS2 GND Door Sensor connect to door swicth to monitor door opening and closing 9 RS 485 Slave units connection up to 8 slave units 10 26 BIT...

Page 6: ...le for each key 1 _ Figure 3 1 M N O m n o 6 A B C a b c 2 P Q R S p q r s 7 D E F d e f 3 T U V t u v 8 G H I g h i 4 W X Y Z w x y z 9 J K L j k l 5 SPACE Cancel call Erase incorrect letter or numbe...

Page 7: ...g in to programming 2 Enter 01 then 3 Enter directory number 2 3 or 4 digits depending on the setup see function code 19 then see Chapter 3 for keypad layout 4 Enter name up to 16 characters name can...

Page 8: ...or keypad layout 4 Enter the a new tenant phone number up to 16 digit then press or press to keep the existing phone number Return to step 3 to edit another tenant directory Function Code 03 Delete Te...

Page 9: ...em can t make calls 1 Log in to programming 2 Enter 05 then 3 Enter 0 disable default pr 1 enable then press Function Code 06 Add New Access Code An access code is a keyless entry code to open the doo...

Page 10: ...atellite system connected to the main system then press 9 Enter 0 no more additional time zone then press and return to step 3 to program another access code 1 add additional time zone then press and...

Page 11: ...to cancel Function Code 09 Access Code Digit 1 Log in to programming 2 Enter 09 then 3 Enter 4 5 6 7 or 8 default setting is 4 digit then press Function Code 10 Add Card 1 Log in to programming 2 Ente...

Page 12: ...tellite system ID 0 7 enter 0 if no satellite connected to the main system then press 9 Enter 0 no more additional time zone then press and return to step 3 to add program another card 1 add additiona...

Page 13: ...Function Code 12 Clear All Cards 1 Log in to programming 2 Enter 12 then 3 Enter 1 to clear all keyfobs or cards press or to cancel Function Code 13 Set Time 1 Log in to programming 2 Enter 13 then 3...

Page 14: ...are stored in the RAM buffer The Event RAM buffer can hold 800 2000 events The Events are stored as first in first out FIFO This function code will clear the event buffer 1 Log in to programming 2 En...

Page 15: ...ay 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press 8 Enter 1 Relay 1 door 1 2 Relay 2 door 2 3 Both relay 1 and 2 then press 9 Return to step 3 to enter another AUS Function Code 17 Ti...

Page 16: ...ry then press 6 Enter end time in military then press 7 Enter 0 Sunday 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday then press Return to step 3 to program more time zone Function Code...

Page 17: ...be assigned for each tenant By default the directory is set to 2 digit but can be changed to 3 or 4 digits The directory can also be used for direct call 1 Log in to programming 2 Enter 19 then 3 Ente...

Page 18: ...relay 2 open door interval see function code 29 2 relay 2 control by AUXIN2 then press Function Code 22 Do Not Disturb If Do Not Disturb is enabled then the calling feature is disabled 1 Log in to pr...

Page 19: ...24 then 3 Enter 0 disable 1 disable system for 60 seconds and local beep default setting 2 disable system for 60 seconds with no beep 3 call directory 0 9 then press Function Code 25 Keypad Beep Turn...

Page 20: ...programming 2 Enter 27 then 3 Enter 10 240 seconds then press Function Code 28 Unlock Relay 1 Time The amount of time for relay 1 to trigger 1 Log in to programming 2 Enter 28 then 3 Enter 01 99 seco...

Page 21: ...l not work Automatic call forwarding will work if the system calls outside line Outside line call forwarding is provided by your local telephone service 1 Log in to programming 2 Enter 31 then 3 Enter...

Page 22: ...code 09 see Chapter 3 for keypad layout 6 Enter name then press 7 Enter 1 relay 1 door 1 2 relay 2 door 2 or 3 both relay then press 8 Enter time zone set 1 3 then press 9 Enter 00 24 hours 20 see fun...

Page 23: ...ate Up to 10 special codes can be programmed 1 Log in to programming 2 Enter 34 then 3 Enter 0 delete 1 add then press 4 Enter code 01 10 then press 5 Enter 4 8 digit code see digit setting on functio...

Page 24: ...gramming Function Code 35 Temporary Card The card will be expired after being used a certain amount of times specified 1 10 times in the programming Up to 10 temporary cards can be programmed 1 Log in...

Page 25: ...hen press and return to step 3 to program another temporary code 1 add additional time zone then press and return to step 8 exit programming Function code 36 Special Card The card can be use to unlock...

Page 26: ...er Sat ID 0 7 then press enter 0 if no satellite connected to the QR5 11 Enter 0 no more additional time zone then press and return to step 3 to program another temporary code 1 add additional time zo...

Page 27: ...e by default remote access for relay 2 is set to 8 see function code 41 If you set relay 1 for key number 8 then you MUST change relay 2 to different key number even though relay 2 is not used 1 Log i...

Page 28: ...remotely DTMF key 7 6 then press Function Code 43 Do Not Disturb Time Zone If you do not want to be disturbed from someone calling you from the system during certain hours of the days you can create...

Page 29: ...ystem s relay can be disabled during certain time but the system is still in full operation Maximum 10 disable time zones 1 Log in to programming 2 Enter 44 then 3 Enter 0 9 then pres 4 Enter 0 Delete...

Page 30: ...Enter relay 1 door 1 then press then press or relay 2 door 2 then press then press Function Code 46 Firmware Version To check the system s firmware version 1 Log in to programming 2 Enter 46 then Func...

Page 31: ...cond delay is plenty of time then press Function Code 49 Edit Existing Access Code Temporary Code and Special Code 1 Log in to programming 2 Enter 49 then 3 Editing an Access Code click here or Editin...

Page 32: ...ystem 1 Direct Call press then directory code see function code 19 2 Scrolling press 3 or 6 to scroll name then press to call the selected name 5 2 Opening Door Remotely Relay 1 door 1 press 9 Relay 2...

Page 33: ...e access to the card reader Other manufacturers card will not work Swipe the card or keyfob as shown below The card reader antenna is mounted behind the black square window 5 5 Extending Talk Time The...

Page 34: ...4 27 2022 8 54 09 AM CHAPTER 6 QWCM Internet IP Module The QWCM Web Based module is included on Q5VOIP Series Click here for QWCM manual QWCM DEFAULT SETTING IP 192 168 1 230 SUBNET 255 255 255 0 GAT...

Reviews: