Chapter 4: Operations
Diagnostic and Maintenance Functions
50
Quantum LTO-9 HH SAS User’s Guide
4
Insert a scratch (blank) data cartridge. The SCD changes to a
flashing
1
and the test begins. During the test, the drive will Unload/
Load the cartridge. Do not remove the cartridge during the test.
• If no error is detected, when the diagnostic ends,
0
temporarily
appears in the SCD, and the tape drive exits Maintenance Mode.
• If an error is detected, the
Fault
light flashes and the drive posts
an error code to the SCD. To determine the error, locate the
code in Error Codes and Messages. To clear the error either turn
the power off and then on again, or reboot the drive by
pressing and holding the Unload button for 10 seconds.
Function Code 2:
Update Drive Firmware
from FUP Tape
Caution:
When updating drive firmware, do not power-off the drive
until the update is complete or the firmware may be lost.
Function Code 2
loads drive firmware from a firmware update (FUP)
tape. The FUP tape must have been created from a LTO-9 tape drive with
the same host interface (e.g. SAS, Fibre Channel).
1
Place the drive in Maintenance Mode. For instructions, see
2
Press the Unload button once per second until
2
appears in the SCD.
(If you cycle past the desired code, press the
Unload
button once
per second until the code reappears.)
3
Press and hold the
Unload
button for three or more seconds, then
release it to select the function. The SCD changes to a flashing
C
.
4
Insert the FUP tape cartridge. The SCD changes to a flashing
2
. The
Fault
light will be
ON
solid during tape movement and flashing
while code is being loaded. The
Ready
light will be
OFF
. The tape
drive loads the updated firmware from the FUP tape into its
erasable programmable read-only memory (EPROM) area.
• If the update completes successfully, the tape drive rewinds and
unloads the FUP tape, resets itself, and is ready to use the new
firmware. The drive automatically reboots.
• If the update fails, the tape drive posts an error code to the SCD.
To determine the error, locate the code in
. Push the
Unload
button to eject the
cartridge. The drive exits Maintenance Mode after the cartridge
Summary of Contents for LTO-9 HH SAS
Page 1: ...User s Guide LTO 9 HH SAS 6 68132 04 Rev A...
Page 8: ...Contents viii Quantum LTO 9 HH SAS User s Guide...
Page 40: ...Chapter 3 Installation Updating firmware 32 Quantum LTO 9 HH SAS User s Guide...
Page 104: ...Appendix A Error Codes and Messages 96 Quantum LTO 9 HH SAS User s Guide...
Page 120: ...Glossary 112 Quantum LTO 9 HH SAS User s Guide...