Chapter 3: DXi6902 FRU Removal and Replacement Procedures
Replacing the Node Chassis
Quantum DXi6902 User’s Guide
157
a
Access the
Service Menu
(see
b
Navigate to
Serial Numbers > Set System Serial Number
.
c
Follow the prompts to set the system serial number.
8
If the DXi6902 is configured for NAS, OST, VTL, or PTT, perform the
following actions:
•
NAS and OST
- Disjoin and rejoin the Active Directory Domain
or Workgroup on the
Configuration > NAS > Windows
Domain
page in the remote management console.
•
VTL and PTT
- Restart the host systems.
9
In the remote management console, delete any administrative alerts
and close any service tickets.
Replacing the Node Chassis
This section describes how to remove and replace the DXi6902 Node
chassis and contains the following sections:
•
•
Obtaining a
Replacement Node
Chassis
Before beginning the replacement procedure, make sure that you have
the required replacement kit. The appropriate replacement Node chassis
will be provided by Quantum Customer Support (see
).
You will need the following items to perform this procedure:
• Replacement Node chassis kit provided by Quantum Customer
Support.
• Masking tape and felt tip marker (for temporarily labeling hard
drives)
• ESD grounding wrist strap (included in the replacement kit)
Summary of Contents for DXi6902
Page 1: ...Field Service Manual Quantum DXi6902 with DXi 3 0 0_69 Software 6 68164 01 Rev A...
Page 8: ...Contents viii Quantum DXi6902 User s Guide...
Page 16: ...Tables xvi Quantum DXi6902 User s Guide...
Page 24: ...Preface xxiv Quantum DXi6902 User s Guide...
Page 242: ...Appendix A DXi6902 Cabling Diagrams 218 Quantum DXi6902 User s Guide...