Chapter 3: DXi6902 FRU Removal and Replacement Procedures
Replacing the Node System Board
152
Quantum DXi6902 User’s Guide
11
Verify that the service tag number was successfully written using the
Service Menu:
a
Access the
Service Menu
(see
b
Navigate to
Serial Numbers > Display Node Serial Number
.
Updating the OEM ID
To update the OEM ID:
1
Connect to the system node via the iDRAC port and launch the
Virtual Console Viewer (see
Connecting to the System Node Using
2
In the left pane of the iDRAC main console, click
Overview > iDRAC
Settings > iDRAC Firmware Update
.
3
Upload the
82DFV_R720_CustBSU.pm
file.
Wait for the iDRAC reboot to complete.
4
Reboot the system.
Wait for the system to complete one more self reboot before the
updated BIOS splash logo displays.
Verifying iDRAC Settings
After replacing the system board, you must verify that certain iDRAC
settings are set to the Quantum required value, and make any changes
as needed:
1
As the system boots, press
F2
to display the
System Setup Main
Menu
.
2
Select
iDRAC Settings
and press
<Enter>
.
3
Select
LifeCycle Controller
and press
<Enter>
.
4
Verify that the following two iDRAC settings are set to
Enabled
:
•
LifeCycle Controller
- Enabled
•
Collect System Inventory On Restart
- Enabled
5
Press
<ESC>
to return to the
iDRAC Settings Menu
.
6
Select
Network
and press
<Enter>
.
Summary of Contents for DXi6902
Page 1: ...Field Service Manual Quantum DXi6902 with DXi 3 0 0_69 Software 6 68164 01 Rev A...
Page 8: ...Contents viii Quantum DXi6902 User s Guide...
Page 16: ...Tables xvi Quantum DXi6902 User s Guide...
Page 24: ...Preface xxiv Quantum DXi6902 User s Guide...
Page 242: ...Appendix A DXi6902 Cabling Diagrams 218 Quantum DXi6902 User s Guide...