Installing the DXi6900 System in the Rack
Quantum DXi6900 Installation Guide
41
For DXi6900 G2 configurations, use the provided 2m mini-SAS HD to mini-SAS HD cables (see
).
Caution:
The Mini-SAS HD plugs can be plugged in upside down. The cable will appear to be
inserted but is not. Verify the cable is seated by pulling lightly on the cable. Verify the SAS link light
is ON after powering on the RBOD. Failure to properly seat the Mini-SAS HD plugs may cause an
installation failure.
DXi6900 G1 Cable Connection Instructions
a. Connect port RBOD1 (slot 5) on the Node to SAS port Ch 1 (Controller A) on RBOD 1.
b. Connect port RBOD1 (slot 6) on the Node to SAS port Ch 1 (Controller B) on RBOD 1.
c. Connect port RBOD2 (slot 5) on the Node to SAS port Ch 1 (Controller A) on RBOD 2.
d. Connect port RBOD2 (slot 6) on the Node to SAS port Ch 1 (Controller B) on RBOD 2.
Figure 29:
DXi6900 G1 SAS Cabling (Node to RBODs)
Port 1
Port 2
ID/
Diag
|O|O|
Port 1
Port 2
ID/
Diag
|O|O|
Port 1
Port 2
ID/
Diag
|O|O|
Port 1
Port 2
ID/
Diag
|O|O|
System Node (Rear)
RBOD 1
RBOD 2
1A
1B
2A
2B
1A
2A
1B
2B
DXi6900 G2 Cable Connection Instructions