![Quantum DXi4510 User Manual Download Page 276](http://html2.mh-extra.com/html/quantum/dxi4510/dxi4510_user-manual_3732247276.webp)
Appendix A: DXi4000 System Specifications
252
Quantum DXi4000 User’s Guide
Caution:
To safeguard backups in the event of a power outage,
Quantum recommends that you connect the DXi4000 to a
UPS (uninterruptable power supply).
Environmental
Specifications
provides various DXi4000 environmental specifications.
DXi4510
Inrush
2.2A @ 100V
0.92A @ 240V
220W
Typical
2.0A @100V
0.83A @240V
200W
683 BTU/Hr
Maximum
7.5A @100V
4.0A @ 240V
750W
DXi4520 and
DXi4601
Inrush
3.0A @ 100V
1.3A @ 240V
300W
Typical
2.0A @100V
0.83A @240V
200W
683 BTU/Hr
Maximum
7.5A @100V
4.0A @ 240V
750W