Quantum|ATL StackLink™ Installation Instructions
Document 6421009-03, Ver. 3, Rel. 0
November 2001
18
Installing the Safety Blanking Panels
Installing the Safety Blanking Panels
0
To avoid personal injury or damage to the StackLink mechanism,
install safety blanking panels over all empty locations in the M1500
stack.
1
If the holes in the rack rails are square (untapped), insert caged
nuts into the holes where the front safety blanking panels will be
installed.
2
Install front safety blanking panels (212579) at the front of the rack,
securing each panel with two screws (YS41803) and washers
(YS40404).
3
Install rear safety blanking panels (212502) at the rear of the rack,
securing each panel with two screws (YS40095).
Cabling the Library
0
The library cabling procedure consists of the following steps:
• Interlibrary (control bus) cabling
• StackLink motor connection
• SCSI bus cabling
• Power cabling