COMMUNICATIONS PROTOCOL
Cubiscan 325 command set
CubiScan 325 Service Manual
58
Factor toggle
This command is used to set the dimensional factor to either domestic or international.
6
1
Line feed
Control
(LF)
0Ah
Negative acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Factor table command
Alpha
(f)
66h
3
1
Neg. acknowledge
Alpha
(N)
4Eh
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Pos
Len
Description
Type
Range
ASCII
Command format
1
1
Start of text
Control
(STX)
02h
2
1
Fact. toggle command
Alpha
(F)
46h
3
1
Dom./Int'l
Alpha
(D/I)
44h or 49h
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Fact. toggle command
Alpha
(F)
46h
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Negative acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Fact. toggle command
Alpha
(F)
46h
3
1
Neg. acknowledge
Alpha
(N)
4Eh
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah
Pos
Len
Description
Type
Range
ASCII