Malfunction without error-no. 

 

In some cases, it will be technically impossible to display an "irregular functioning" of the installation 
by a definite error number. An alleged error may by all means also be due to "correct" causes. 
For this reason the list shown hereafter has been established, which contains the probable or 
already encountered irregular functioning, their possible causes as well as the corrective action 
(error elimination) to be taken.

 

 

Malfunction 

Analysis 

Possible causes 

Remedy 

Drive unit fails to react: 
• No automatic opening. 
• No reaction on the 
control elements (side 
cover/D-Bedix). 

• LED 5 V (green) on the 
control is not lighted. 

Power supply voltage is 
missing. 

• Measure the mains supply 
voltage, check its cabling and 
eliminate any detected 
deficiencies. 

Drive unit fails to open. 

• LED SE (safety element, 
yellow) is lit. 
• Determine the active safety 
element via the diagnostic 
level. 

One or more safety 
elements are active or 
incorrectly cabled. 

• Remove the obstacle. 
• Check the cabling between the 
safety element and the control 
unit, and eliminate any detected 
deficiencies. 
• Replace the safety element. 

• LED SE (safety element, 
yellow) is not lighted. 
• LED OE (opening command, 
blue) reacts to the opening 
element. 
• Determine the opening 
element via the diagnostic 
level. 

Depending on the enabled 
operating mode, the opening 
commands (inside/ 
outside, etc.) are ignored. 

• Change the operating mode. 
• Correct the cabling of the 
opening elements. 

• LED SE (safety element, 
yellow) is not lighted. 
• LED OE (opening command, 
blue) is not lighted despite the 
active opening element. 

The opening command is 
not evaluated. 

• Check the cabling between the 
opening element and the control 
unit and eliminate any detected 
deficiencies. 
• Replace the opening element. 

Drive unit fails to close. 

• LED SE (safety element, 
yellow) is lit. 

One or more safety 
elements are active or 
incorrectly cabled. 

• Remove the obstacle. 
• Check the cabling between the 
safety element and the control 
unit and eliminate any detected 
deficiencies. 
• Replace the safety element. 

• LED SE (safety element, 
yellow) is not lighted. 
• LED OE (opening command, 
blue) is lit. 

An opening command is 
pending. 

• Check the cabling between the 
opening element and the control 
unit and eliminate any detected 
deficiencies. 
• Replace the opening element. 

• Check the operating mode. 

The operating mode OPEN 
is active. 

• Change operating mode. 

The operating mode 
cannot be changed. 

• The program switch in the 
side cover fails to react. 

Program switch cable is not 
plugged in. 

• Check the cable and eliminate 
any detected deficiencies. 

• The operating mode symbol 
on the display is underlined. 

The operating mode is 
overridden via connection 
terminal X110. 

• Change the operating mode by 
means of the external program 
selector switch. 
• Correct the cabling of the 
external program selector switch. 

Prior to commissioning: 
During manual opening, 
the door leaf encounters 
an important resistance 
and closes at high speed. 

 

The motor connector plug 
is not connected. 

• Plug the motor connector plug 
into the socket 
 

 

 

Summary of Contents for FD 10

Page 1: ...Swing door drive unit FD 10 pilot series Mounting and operating instructions Com no Pos Year of construction Operator Operating place...

Page 2: ...justments 19 7 1 Motion parameters PARAMETER 19 7 2 Configuration CONFIG 20 7 3 Installation with multiple door leaves Double Door 21 8 Menu navigation 22 8 1 PARAMETER 22 8 2 CONFIG 22 8 3 DOUBLE DOO...

Page 3: ...anent torque output shaft 56 Nm Short term torque output shaft 165 Nm Distance door hinge Output shaft Lintel mounting 100mm 160mm GSD Lintel depth Normal rods max 250mm Sliding rods pl 50 150 mm pull...

Page 4: ...tel mounting Lintel depth Option Axle extension Standard none 10 18 36 0548 190 10 10 28 46 0548 191 20 10 38 56 0548 192 30 10 48 66 0548 193 40 10 58 76 0548 194 50 10 68 86 adjust dimensions accord...

Page 5: ...the consequence that some measures will change 28mm and thus need to be adapted accordingly Lintel depth mm Max door opening angle 0 50 105 51 100 100 100 150 95 Option Axle extension Standard none 33...

Page 6: ...thus need to be adapted accordingly Option Axle extension Standard none 10 18 40 0548 190 10 10 28 50 0548 191 20 10 38 60 0548 192 30 10 48 70 0548 193 40 10 58 80 0548 194 50 10 68 90 adjust dimensi...

Page 7: ...e The fixing holes of the drive module must always be on the side facing the door hinge 2 Fasten the chassis by means of six screws M6 to lintel 3 Fasten the drive module by means of four screws M5 to...

Page 8: ...nction the arrow with description PULL points to the chassis 4 Route the reference switch cable the mains cable and program switch cable on the side cover below the drive module 5 Screw earth cable to...

Page 9: ...le the reference switch cable and program switch cable into the control unit c Fasten the control unit by means of three screws M5 to the chassis d For sliding rods with pulling function first release...

Page 10: ...ace side of the control unit 7 If required route the cable for sensors motor lock button etc below the drive module and the control unit and connect them 8 Mount the selected rods according to drawing...

Page 11: ...slight hit onto the screw heads b Open the door leaf to the desired maximum opening angle c Turn the stop piece till it stops and retighten the screws 6Nm 1 Open the door leaf and let it close by mea...

Page 12: ...t the power supply into the mains supply terminal b Fasten the power supplies with the strain relief clip onto the side cover c Insert mains cable into the mains supply terminal 3 Fasten both side cov...

Page 13: ...er commissioning a Degrease the glued surface on the covering b Remove white sticker protective sheet D c Affix the stencil B with the Logo C on the lower right corner of the covering and press on wel...

Page 14: ...only act upon the Master single leaf operation Opening elements connected to Slave act upon the Master as well as on the Slave bi parting operation The safety elements SER and SES are connected to th...

Page 15: ...desired time lag of the closing angle Note In cases where a mechanical closing sequence regulator is used start with a AcSeq of 90 6 Configuration of the Slave drive unit DubleD SlaveA AoSeq desired t...

Page 16: ...tic closing upon expiration of the adjustable hold open time MANUAL position 0 The drive mechanism and the control elements are switched off The door leaf can be manually opened The door leaf is close...

Page 17: ...ward once the display direction is switched to a readable position 3 Programming the type of rods Rod Move the joystick to the left to the right Validate the correct type of rods by means of OK In the...

Page 18: ...ed closing direction 11 Upon completion of the first learning run the following message is displayed 12 The display should immediately supply the following information 13 By means of an opening comman...

Page 19: ...Door rectification time time press close 0 0 4 0 s 0 5 s FLock Pressing force during locking force lock only effective if TLock is 0 0 0 7 0 A 2 0 A FSlam Accelerating function force slam 0 10 OFF FWi...

Page 20: ...e if relay PCB 0 is plugged in OPEN RC 0 3 Parametrizable relay output 3 on optional PCB 1 only visible if relay PCB 0 is plugged in ERROR RC 0 4 Parametrizable relay output 4 on optional PCB 1 only v...

Page 21: ...eD Closing sequence role Master Slave and interlock side A B OFF MastrA SlaveA MastrB SlaveB OFF AoSeq Current delay angle for opening sequence control Slave only visible if DubleD is active 0 110 20...

Page 22: ...etection EMY Emergency element PUGO Push and Go 2nd display line at the bottom left hand side the presently enabled operating mode is displayed a frame around the symbol indicates the overriding opera...

Page 23: ...s value is memorized 8 5 ERROR ACTIVE Pending active errors The pending active errors are displayed in a list This list is updated at the end and the latest additions appear during the next passage A0...

Page 24: ...any other joystick movement The setting up procedure can be canceled by means of the D BEDIX C key Setting of the opening angle Ao During the first setting up run the drive unit moves to the open posi...

Page 25: ...tching point of the reference switch The reference switch must be activated in the closed position switching contact open Open position F 02 Not detected in the closed position Prior to the first sett...

Page 26: ...resp under voltage E32 01 24 V Safety Over resp under voltage Overload short circuit 24 VDC onto terminals X105 or X107 E33 01 24 V E Lock Error Over resp under voltage Overload short circuit 24 VDC...

Page 27: ...ct the cabling of the opening elements LED SE safety element yellow is not lighted LED OE opening command blue is not lighted despite the active opening element The opening command is not evaluated Ch...