7.2
Configuration
(CONFIG)
Parameter Description
Setting range
Default
APuGo
Triggering angle Push&Go (angle push&go)
OFF, 2...10°
OFF
ASES
1) Suppression point Safety Element stop.
If Ao is changed, ASES is automatically set to Ao.
45°...Ao
95°
ASER
2) Suppression range of the safety element reversing
0...60°
0°
SeOpCo
Persistent opening
After a Safety Element Stop during the opening procedure, the door shall
continue its opening move, as soon as SES is activated
.
OFF
ON
OFF
SeOpTi
Waiting time till the drive unit closes even if SeOpCo = ON closes,
in the event that a fixed object blocks the doors
(only visible if
SeOpCo = ON)
PERMAN
1...60 s
20 s
SESClo
Safety element Stop activated/deactivated during the closing
motion
ACTIVE
INACTI
INACTI
EMY-IN
Configuration of the Emergency terminal (break contact)
CL-SPR
(spring)
STOP
OPEN
CL-MOT
(motor)
CL-SPR
OExStp
Step-by-step control function
OFF
OEI
OEO
KEY
RADIO
OFF
RC 0.1
Parametrizable relay output 1 on optional PCB 1
(only visible if relay PCB 0 is plugged in)
CLOSED
OPENING
OPEN
CLOSING
ERROR
PSAUTO
PSNIGHT
PSEXIT
PSOPEN
PSMANU
GONG
LOCKED
SIX30S
EMY_AL
CLOSED
RC 0.2
Parametrizable relay output 2 on optional PCB 1
only visible if relay PCB 0 is plugged in)
OPEN
RC 0.3
Parametrizable relay output 3 on optional PCB 1
only visible if relay PCB 0 is plugged in)
ERROR
RC 0.4
Parametrizable relay output 4 on optional PCB 1
only visible if relay PCB 0 is plugged in)
GONG
RC 1.1
Parametrizable relay output 1 on optional PCB 2
(only visible if relay PCB 1 is plugged in)
OPENING
RC 1.2
Parametrizable relay output 2 on optional PCB 2
only visible if relay PCB 1 is plugged in)
CLOSING
RC 1.3
Parametrizable relay output 3 on optional PCB 2
only visible if relay PCB 1 is plugged in)
PSAUTO
RC 1.4
Parametrizable relay output 4 on optional PCB 2
only visible if relay PCB 1 is plugged in)
LOCKED
Unlock
Impulse/permanent unlocking
IMPULS
PERMAN
IMPULS
EL-Fb
Return signal of the electric lock
N.O. -> Contact open if in the unlocked state (-), .closed if in the locked state (+)
N.C.
->
Contact open in the locked state (+), closed in the unlocked state (-)
OFF
N.O.
N.C.
OFF
LockAU
Operating mode AUTOMATIC locked
(only visible if Unlock = Perman)
UNLOCK
LOCK
UNLOCK
LockEX
Operating mode EXIT locked
(only visible if Unlock = Perman)
UNLOCK
LOCK
LOCK
LockMA
Operating mode MANUAL locked
(only visible if Unlock = Perman)
UNLOCK
LOCK
UNLOCK
LcdDir
Orientation of the display
0...1
0
MovCon
Endurance test Open/Close
OFF
ON-FLT
ON-PRM
OFF
OExMAN
Acceptance of opening commands after a manual door opening
(only if APuGo = OFF)
OFF
ON
OFF