Chapter 2
26
KEMX-6000 User’s Manual
Table 5 JP3 Panel Backlight Power Selection for LVDS2
2
1
6
5
Jumper
Setting
Status
1
1-3
Backlight Power = +12V
3-5
Backlight Power = +5V
2
2-4
Panel Power = +3.3V
4-6
Panel Power = +5V
Pitch: 2.54mm [YIMTEX 3362*03SAGR]
Table 6 JP4 Signal / Power Selection for COM6
10
1
9
2
Jumper
Setting
Function
1
1-3 Short
Pin 1 = +12V
3-5 Short
Pin 1 = +5V
5-7 Short
Pin 1 = +5V
7-9 Short
Pin 1 = DCD
2
2-4 Short
Pin 9 = +12V
4-6 Short
Pin 9 = +5V
6-8 Short
Pin 9 = +5V
8-10 Short
Pin 9 = RI
Pitch: 2.54mm [YIMTEX 3362*05SANGR]
Table 7 JP5 Panel Backlight Power Selection for LVDS1
2
1
6
5
Jumper
Setting
Status
1
1-3
Backlight Power = +12V
3-5
Backlight Power = +5V
2
2-4
Panel Power = +3.3V
4-6
Panel Power = +5V
Pitch: 2.54mm [YIMTEX 3362*03SAGR]
Table 8 JP6 Backlight Power Enable Selection for LVDS1
2
1
6
5
Jumper
Setting
Status
1
1-3
Backlight
Enable
Voltage = +3.3V
3-5
Backlight
Enable
Voltage = +5V
2
2-4
Active High
4-6
Active Low
Pitch: 2.0mm [PINREX 222-97-03GBB1]