![Qualstar TLS-4000 Technical & Service Manual Download Page 53](http://html1.mh-extra.com/html/qualstar/tls-4000/tls-4000_technical-and-service-manual_3421438053.webp)
CAUTION
Executing a RESET SCSI BUS Command could adversely affect another device or
host system that is connected to the same SCSI bus. Use this command with great
caution!
To Reset the SCSI Bus:
1.
Press the MENU key to open the Top Menu.
2.
Use the (DOWN) key to move the pointer to Private, then press the ENTER
key to open the Private menu.
3.
Use the (UP) or (DOWN) key to move the pointer to RESET SCSI BUS.
4.
Press the ENTER key to execute the RESET SCSI BUS command.
NOTE
The RESET SCSI BUS command is locked by both the Master Security Lock and the Inventory
Lock. If the user gets a SECURITY message, the user must first unlock the security locks before
proceeding. Use the procedure in section 5.2 to enter the Security menu and disable the Master
Security Lock. The user can also disable the Inventory Lock while the Security menu is displayed.
5.4.4 The Private\Calibration Data Status Screen
P........Calibration
Calibrated: NO
Valid: NO
CRTPRS Thrs:ddddd
I/OCLR Thrs:ddddd
I/OFULL Thrs:ddddd
YCLEAR Thrs:ddddd
YCLEARM Thrs:ddddd
Y DATA 0:
±
ddddd
Y Drive Ofst0:
±
ddd
Y Drive Ofst1:
±
ddd
Y Drive Ofst2:
±
ddd
Y Drive Ofst3:
±
ddd
Y FIXED 0:
±
ddddd
Y FIXED 1:
±
ddddd
Y I/O PORT:
±
ddddd
Y PRIVATE:
±
ddddd
Y SHUTTLE:
±
ddddd
Y STORY 0:
±
ddddd
The Calibration Data Status screen displays the calibration data determined by the
CALIBRATION command. If, for example, the user encounters some particularly dif-
ficult Handler problem, it may become necessary to relay the data on this screen to a
Qualstar Technical Support technician.
5-10
The Private Menu
501380 Rev. B