RS485A, RS485 or RS485I (Executive IV PCBA’s only)
These connectors are keyed.
CAUTION
To avoid equipment damage, be sure that all pins on the 12VFANS cable’s plug
mate correctly with all pins on the 12VFANS connector on the Executive PCBA.
•
CARAGE
(Carriage)
•
OPTO
This connector is keyed.
•
DRVBAY
(Drive Bay)
12.
Reinstall the Rear Service Panel, then use a number 2 Phillips screwdriver to re-
install all six Rear Service Panel mounting screws (Figure 7-30).
13.
Open the cabinet door.
7.14.3 Reconfiguring the TLS
CAUTION
To prevent possible injury or equipment damage, BEFORE APPLYING POWER af-
ter the Executive PCBA is replaced, MAKE SURE THE CABINETDOOR IS OPEN.
When power is applied to the TLS while the cabinet door is open, no TLS motors
will operate. The configuration information in the new Executive PCBA must be
updated to match the library’s installed hardware, BEFORE any TLS motors are al-
lowed to operate.
1.
Make sure that the cabinet door is open
, then reconnect the power cord and turn
on the TLS power.
NOTE
Both the +12V and +5V LEDs at the top of the Executive board must light.
Confirm that the Front Panel display lights and that characters are displayed.
2.
Inspect the label on the rear-panel to determine the unit’s model number.
NOTE
If the TLS was upgraded in the field to a larger model, the rear-panel label may not indicate the
correct, current model number.
7-50
Field–Replaceable Units (FRUs)
501380 Rev. B