7-30
Field–Replaceable Units (FRUs)
511010 Rev. 07-01-19
7.15.1
Replacing an Air Filter in a RLS-85XX library
Figure 7-26 Air Filter with a Storage Matrix Open (RLS-85XX shown)
1.
Slide the storage matrix forward until the air filter can be accessed.
2.
Grasp the air filter and lift the nearest edge while pulling back the air filter tab
to release it from the tab.
3.
Replace the air filter with a new one (Qualstar P/N 500584-01-6). If an old air
filter is not yet dirty enough to be replaced and is being reinstalled, make sure
that the side that was facing the inside of the library is placed in the same direc-
tion as it was when it was removed. Reversing the direction of an old air filter
may cause dirt to be transferred into the library.
4.
Slide the air filter past the air filter tab until it is touching the stops on the stor-
age matrix front panel, and then turn it while pulling back the air filter tab until
it pops securely under the tab.
5.
Slide the storage matrix closed and lock it.
6.
Repeat these steps for the second storage matrix if installed on the library.
Front of