7) The display should now show
ct / Fd
as shown
in Figure 15-A. This indicates Control Type Meter
Delayed Mode. Do not change this value and press
the REGEN button to advance to the next setting
8) The display should now show
nt / ---1
as shown
in Figure 15-B. This indicates the number of tanks
is one. Do not change this value and press the
REGEN button to advance to the next setting
9) The display should now show
c / 32.0
. This
indicates the Capacity is 32,000 grains.
i
use
the uP or doWn button to change this
value to the one listed on page 4/calculated
and press the REGEN button
as shown in Figure 15-C
10) The display should now show
H / 20
. This
indicates the Hardness is 20 gpg.
i
use the
uP or doWn button to change this value to
the total hardness level of your water listed
on page 4/calculated on pages 6 and 7
and
press the REGEN button as shown in Figure 15-D
11) The display should now show
rS / SF
as shown
in Figure 15-E. This indicates that the Reserve
Selection is Safety Factor percentage. Do not
change this value and press the REGEN button
to advance to the next setting
12) The display should now show
SF / 10
. This indi-
cates the Safety Factor is 10%. This means the
system will leave 10% of the softening capacity
for the day before regeneration.
use the uP
button to change the value to 15%
and press
the REGEN button as shown in Figure 15-F