Help: 888-426-5001
QualityWaterForLess.com
5 › M a k I n G t H e b r I n e ta n k c o n n ec t I o n
1) Attach the brine nut, tapered ferrule, metal tube
insert, and brine line screen to one end of the
included brine tubing as shown in Figure 11-A.
i
Be sure that the tapered side of the black
ferrule faces away from the end of the brine
line and that the tapered side of the white
ferrule faces towards the end of the brine line
2) Next, connect this prepared end of the tubing
to the Fleck 2510 SXT Meter Valve as shown in
Figure 11-B. Tighten the nut to the valve using
a wrench until snugly in place. Be careful not to
over tighten, as you may sever the brine line
3) Locate the brine well and remove the cap.
You
may also take this moment to prepare and
insert the brine support grid determined
from pages 6 and 7
. Then pull the
474 Brine
Float assembly
out of the brine well as shown
in Figure 11-C
4) Next, fix the 474 Brine Float Assembly to the
brine well through the pre-drilled hole and
hand-tighten as shown in Figure 11-D
f I G u r e 11- a
f I G u r e 11- b
f I G u r e 11- c
f I G u r e 11- e
f I G u r e 11- d
f I G u r e 11- f
5) Take the other end of your brine line tube, make
sure this end is clean cut, recut if it is not clean,
mark 3/4” from the end of the tube, and insert the
tube through the small hole drilled through the brine
tank and brine well (Figure 11-E)
6) Firmly insert the tubing end 3/4” into the tube
opening on the 474 Brine Float Assembly as
shown in Figure 11-F.
i
Make sure the tube is
fully inserted into the assembly