Model Q4P07
Installation, Operation and Maintenance
4
Rev. 12/26/2013
Q4P07-IOM-Q.doc
WARNING
V
ERTICAL
C
LEARANCE
Check the height of the area where the lift is to be
installed. Clearance should be calculated based on
the full raised height of the lift.
Failure by purchaser to
provide adequate clearance
could result in unsatisfactory
lift performance, property damage, or personal
injury.
F
LOORING
Be certain you have the proper concrete floor to
properly handle the loaded lift. Floor should be in
generally good condition with no large cracks,
spalling or deterioration.
Minimum requirements for concrete are 4 inches
minimum depth, with steel reinforcement, 3500
psi, cured for 28 days per local commercial
practice
. This lift is designed to accommodate a 3
inch total variation in elevation at the base of the
four posts. Floor should be level within 1/2 inch
from side-to-side and 2 1/2 front-to-rear to avoid
special shimming. No anchors should be installed
within 8 inches of any crack, edge, or expansion
joint. If these conditions cannot be met, a pad may
be poured to accommodate the lift.
A qualified person should be consulted to address
seismic loads and other local or state requirements.
Failure by purchaser to
provide the recommended
mounting surface could
result in unsatisfactory lift performance,
property damage, or personal injury.
L
OCATION
This lift has been evaluated for indoor use only with
an operating ambient temp. range of 5 – 40°C
(41-104°F)
E
LECTRICAL
R
EQUIREMENTS
For lift installation and operation with standard
power unit, it is necessary to have a dedicated 115V
single-phase 60-cycle circuit with a 20 amp circuit
breaker or time delay fuse.
For lift installation and operation with 230V power
unit, refer to
Fig 24
.
S
AFETY
N
OTICES AND
D
ECALS
For your safety, and the safety of others, read and
understand all of the safety notices and decals
included here.
R
EAD ENTIRE MANUAL BEFORE ASSEMBLING
,
INSTALLING
,
OPERATING
,
OR SERVICING THIS
EQUIPMENT
.
P
ROPER MAINTENANCE AND INSPECTION IS
NECESSARY FOR SAFE OPERATION
.
DO
NOT
OPERATE A DAMAGED LIFT
.
Safety decals similar to those shown here are found
on a properly installed lift. Be sure that all safety
decals have been correctly installed on the Power
Unit reservoir. Verify that all authorized operators
know the location of these decals and fully
understand their meaning. Replace worn, faded, or
damaged decals promptly.
Do not attempt to raise a
vehicle on the lift until the
lift has been correctly
installed and adjusted as described in this
manual.
WARNING
WARNING