24
March 17, 2020
7080-166J
Following correction of any alarm, the user interface will turn to OFF. Turn user interface back ON and back to desired setting.
ALARM
POSSIBLE CAUSE
CORRECTIVE ACTION
Feed Error
Hopper empty
Fill the hopper
Auger jam
Inspect the feed tube for jams
Vacuum switch not closing
Make sure firebox door is shut, vacuum hose is connected to
switch and drop tube, wire connectors are connected to vacuum
switch, control board, hopper switch, and safety snap disc.
Hopper lid open
Close the hopper lid
Exhaust probe does not sense temperature
Secure the exhaust probe keeping its wire away from hot
surfaces and clean the exhaust plenum
Snap disc tripped
Reset snap disc
Exhaust probe not attached to exhaust
blower properly
Secure exhaust probe to exhaust blower housing – keeping its
wire away from hot surfaces
Exhaust path is dirty
Clean unit including the fire pot, exhaust path, and
venting system
Ignition Error
Hopper empty
Fill the hopper
Feed motor doesn’t turn
Inspect feed motor circuit (hopper lid must be closed, vacuum
switch must be closed, snap disc closed, and feed motor must
be plugged in)
Clear jam in feed tube
Dirty appliance
Clean unit including the fire pot, exhaust path, and
venting system
Igniter has no power or is defective
Check igniter lead connections or replace igniter
Exhaust probe not properly installed
Secure exhaust probe to exhaust blower housing – keeping its
wire away from hot surfaces
Igniter chamber plugged with debris
Clean igniter chamber
2 Exhaust Probe Fail
Not connected to the control board
Connect terminal end to control board
Failed component
Replace exhaust probe – securing it to exhaust blower housing
– keeping wire away from hot surfaces
6 Exhaust
Blower Alarm
Wire from exhaust blower or encoder is
disconnected or shorted
Make sure wire is not damaged / melted and ends are fully
connected to the encoder and control board.
Defective exhaust blower
Replace exhaust blower
Defective encoder (on end of exhaust
blower)
Replace exhaust blower
8 Exhaust Over-Temp
Feed Motor Locked On
Repair wire(s) and replace control board
Non-approved fuel used
Only use wood pellet fuel. Do not enhance its performance with
any other combustible substance.
Convection blower dirty
Clean impellers
10
Communication Error
Bluetooth Key does not have power (blue
light on key is not on)
Plug appliance into power source
USB extension cable not plugged in
Bluetooth key not plugged in.
Replace Bluetooth Key
Replace USB extension cable not plugged in
Replace control board
Bluetooth Key and user interface not paired
Pair Bluetooth Key and user interface
User interface experiencing
communication interruption
Move user interface closer to the Bluetooth Key or to another
location (within 30 feet)
Remove any obstructions between user interface and
Bluetooth Key
C. User Interface Alarm
Table 24.1