12
March 17, 2020
7080-166J
Figure 12.1
8:30 AM
TUNING
N. Clear Space
O. Tuning
(Factory default setting is 5)
The function of tunning is to allow for variations in
elevation, venting and installation configurations, and fuel
types (hard wood/soft wood).
Rotating this dial will adjust the air/fuel ratio to
the appliance:
• Increase the tunning number to increase the
flame height.
• Decrease the tunning number to decrease
flame height.
•
Adjust 1 level at a time, allowing 15 minutes for fire to
stabilize before making another adjustment.
A properly adjusted fire will have a bright, active flame
pattern that extends out of the fire pot approximately 6 to 9
inches when burning on high. A properly adjusted fire will
burn cleaner and have higher efficiencies.
NOTICE:
Clearances may only be reduced by means
ap proved by the regulatory authority
having jurisdiction.
Mantel:
Avoid placing candles and other heat-sensitive ob jects
on mantel or hearth. Heat may damage these objects.
WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
•
Fire pot floor open.
Do NOT store fuel:
• Closer than required clearances to
combustibles to appliance
• Within space required for loading or
ash removal.