Quadra-Fire • QV36DB-A • 2018-900 Rev. F • 12/07
31
Placing the Ember Material
• Release the four glass latches on the glass frame. Re-
move glass door from the unit.
•
Glowing Ember
material can be placed without remov-
ing logs. Place a single layer of dime size and thickness
pieces on exposed area of burner front and burner cen-
ter. Starting in front of two center logs place one row at a
time, completely surrounding all ports in front of middle
logs including those that extend under front logs.
DO
NOT
press ember material down into ports or place more
than a single layer on burner. Do not place embers on or
near ports behind front logs.
CAUTION: DO NOT COVER BURNER PORTS WITH EM-
BER MATERIAL.
___________________________________________
Shutter Settings
NG
LP
Burner Full Open
Full Open
• Save the remaining ember materials for use during fire-
place servicing.
• Replace the glass door.
• Pull out and latch the glass clips into the glass frame.
• Install a decorative front.
Glass Specifications: CERAMIC
Positioning the Logs
Refer to the included log instructions.
Step 11. Before Lighting the Fireplace
Before
lighting the fireplace, be sure to do the following:
Remove all paperwork from underneath the fireplace.
Check that log retaining rubber bands have been
removed!
Review safety warnings and cautions
• Read the
Safety and Warning Information
section at
the beginning of this
Installers Guide
.
Double-check for gas leaks
• Before lighting the fireplace, double-check the unit for
possible gas leaks.
Double-check vent terminations and front grilles for
obstructions.
• Before lighting the fireplace, double-check the unit for
possible obstructions that could be blocking the vent ter-
minations or the front grilles.
Double-check for faulty components
• Any component that is found to be faulty
MUST BE
re-
placed with an approved component. Tampering with the
fireplace components is
DANGEROUS
and voids all war-
ranties.
A small amount of air will be in the gas supply lines. When
first lighting the fireplace, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the fireplace will light and will operate normally.
Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines,
unless
the gas
valve has been turned to the OFF position
, in which
case the air would have to be purged.
NOTE:
The fireplace should be run 3 to 4 hours on the initial
start-up. Turn it off and let it cool completely. Remove and
clean the glass. Replace the glass and run the fireplace for
an additional 8 hours. This will help to cure the product
used in the paint and logs.
During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the fireplace’s initial burning.