VOYAGEUR

Figure 19.1 

  

Grille hinges 

downward

Remove Screws & 

Pull Access Assembly 

away from Insert

Remove Outside Cover 

Plate A 

(Discard)

Figure 19.2

  

Outside Air Cover 

Plate B 

(Discard)

Termination 

Cap

Flex Adapter

Items Needed for Installation (not supplied)

 • 4 inch fl ex aluminum pipe, or if using alternate material, 

then it shall be made from durable, non-combustible, heat 
resistant material up to 350

o

F.  Cut the pipe to the required 

length for your installation. 

  •  Phillips head screw driver 
 • 

5/32 

Allen 

Wrench 

 • 

Silicone 

sealant

A. Outside Air Kit Installation

A source of air (oxygen) is necessary in order for combustion 
to take place.  Whatever combustion air is consumed by the 
fi re must be replaced.  Air is replaced via air leakage around 
windows and under doors. In homes that have tightly sealed 
doors and windows, an outside air source is needed. An optional 
Outside Air Kit is available. 

WARNING

Do not draw outside combustion air from:

• Wall, 

fl oor or ceiling cavity

•  Enclosed space such as an attic or garage
•  Close proximity to exhaust vents or 

chimneys

Fumes or odor may result

Fire Risk.

Asphyxiation Risk.

Asphyxiation Risk.

Outside air inlet must be located to prevent 
blockage from:

• 

Leaves, snow, ice or other debris

Block may cause combustion air starvation

Smoke spillage may set off alarms or irritate sensitive indi-
viduals.

WARNING

Asphyxiation Risk.

Length of outside air supply duct shall NOT exceed 
the length of the vertical height of the exhaust fl ue.

• 

Fire will not burn properly

  Smoke spillage occurs when door is opened due 

to air starvation.

WARNING

If Not Installing the Outside Air Kit

1.  Swing grille down to expose the two screws.  

Figure 

19.1

2.  Remove the two screws and pull the access assembly 

away from the appliance.

3.  Remove the outside air cover plate A and discard.

4.  Re-install the access assembly.

Option One - Outside Air Installation Instructions

1.  Remove the outside air cover plate B on outer can and dis-

card.   

Figure 19.2.

2. Install optional fl ex adapter to outer can with the same 

screws.  Do not use plastic wire ties that come with the kit 
as they will melt.  NOTE:  You may need to install the fl ex 
pipe into the fi rebox  fi rst depending on installation. Attach 
fl ex to adapter with at least 2 screws.

3.  Ensure existing access hole in fi replace is suffi cient to feed 

the 4 inch fl ex.

4.  After sliding can into fi replace, feed fl ex into cut opening to 

obtain outside combustion air.

5.  Level outer can and install appliance.  See 

page 20.

Option Two - Installation Instructions

1.  Remove the outside air cover plate on outer can and dis-

card and reuse the 4 screws

2.  Ensure existing access hole in fi replace will not be covered 

by the outer can. Existing outside air intake hole may be 
under at the rear or side of outer can.  Outside air may also 
enter down existing chimney chase in some situations.

3.  Repeat steps 5 through 9 above with one exception.  After 

installing the appliance in the outer can, seal the fi replace 
opening and trim package with insulation to prevent air leak-
age into the room.

Appliance Set-Up

Summary of Contents for Quadra-Fire VOYAGEUR-MBK

Page 1: ...other appliance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING Fire Risk For use with solid wood fuel only Other fuels may overfire and generate poisonous gases i e carbon monoxide Installation and service of this appliance shou...

Page 2: ...all Checklist 7 3 Dimensions and Clearances A Appliance Dimensions 8 B Clearances to Combustibles 9 C Calculating Alternate Floor Protection 11 D Locating Your Stove Chimney 12 E Chimney Termination Requirements 12 F 2 10 3 Rule 13 4 Chimney Systems A Venting Systems 14 B Inspections 14 C Larger Chimneys 14 D Masonry Chimney 14 E Metal Heat Circulating Masonry 16 F Prefabricated Metal Chimney 16 G...

Page 3: ...tside combustion air inlet is provided The structural integrity of the mobile home floor ceil ing and walls must be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used Outside Air Kit part OAK ACC must be installed in a mobile ho...

Page 4: ...ile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method for Behavior of Metals in a Vertical Tube Furnace of 750 C F Combustible Materials Material made of or surfaced with any of the following ma terials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or un plastered ...

Page 5: ...d national codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION WARNING DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM May allow flue gases to enter the house Asphyxiation Risk Installation and use o...

Page 6: ...air handler joints and seams taped or sealed Basement installations should be avoided D Tools And Supplies Needed Before beginning the installation be sure the following tools and building supplies are available Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety gla...

Page 7: ...inimum height requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 8 Combustible materials not installed in non combustible areas Verified all clearances meet installation manual requirements Mantels and wall projections comply with installation manual requirements Protective hearth strips and hearth extension installed per manual requirements A...

Page 8: ...16 in 37mm Surround Sizes A B Metal Surround w Cast Trim STD 42 5 in 1080mm 30 in 762mm Metal Surround w Cast Trim LRG 48 in 1219mm 34 in 864mm All Cast Surround 40 in 1016mm 30 in 762mm Metal Surround w Stnd Trim STD 43 in 1092mm 31 in 787mm Metal Surround w Stnd Trim LRG 51 in 1295mm 34 in 2184mm A B 30 degree 30o A B Vertical Figure 8 3 Side View With Optional Offset Adapter Flue Adapter A B Ve...

Page 9: ...m 5 ft length 1 82m 6 inch 152mm diameter flue liner is required as per UL 1482 SIDE TRIM 3 4 max SIDE WALL TOP TRIM 3 4 max 21 1 4 540mm 31 1 4 794mm HEARTH EXTENSION USA 18 3 4 CANADA 22 3 4 578mm 40 3 16 1021mm FIREPLACE FRONT SURFACE USA 17 7 16 CANADA 19 7 16 494mm HEARTH EXTENSION 47 3 16 1199mm 12in max MANTEL See next page for thermal protection requirements Required Protection Suggested P...

Page 10: ...ld Solid Fuel Fireplace Floor Protection Under Hearth Extension Figure 10 1 Thermal Protection Required SAFETY TESTING NOTES During safety testing the following material was used for the floor protection material under the hearth extension USA 1 4 inch 6 25 mm James Hardi Board R 0 52 1 inch thick non combustion board with a value of R 2 04 is required See Alternative Floor Protection Worksheet on...

Page 11: ...ial s resistance to heat transfer R value is convenient when more than one material is used since you can add the R values together whereas you can not do this for k value The HIGHER the R factor means less heat is being conduct ed through the non combustible material to the combustible material beneath it The R value of a material must be equal or larger then the required R value to be acceptable...

Page 12: ...ll through the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures ...

Page 13: ...Minimum 3 ft 91cm Minimum Wall or Parapet F 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimney connector as the flue collar on the unit Changing the diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea...

Page 14: ...r cleaning and re installation When possible install an airtight clean out door to the rear of the smoke shelf A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be 6 inches 152mm minimum diameter stainless steel connector pipe Chimney The chimney can be new or existing masonry or prefabricated and must meet the following minimum requirements as specified below...

Page 15: ...cordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in Chimney Combustible Floor Masonry Chimney Cont d This insert conforms with the UL 1482 and ULC S628 Canada in all respects and is approved to UL ULC safety standards for installation and use within a fireplace with a masonry chimney in accordance with NFPA 211 and ...

Page 16: ...lue collar and the chimney top The air flow of the factory built zero clearance fireplace system must not be altered The flue liner top support attachment must not reduce the air flow for the existing air cooled chimney system No dilution air is allowed to enter the chimney 1 Secure the fireplace damper in the open position If this cannot be accomplished it will be necessary to remove the damper 2...

Page 17: ...orted Manufacturer designed adjustable support kit can be ordered from your dealer Final approval of this installation type is contingent upon the authority having jurisdiction Fire Risk When lining air cooled factory built chimneys Run chimney liner approved to UL 1777 Type HT requirements 2100 degrees F Re install original factory built chimney cap ONLY DO NOT block cooling air openings in chimn...

Page 18: ...ng 25 feet 7 62m from base of appliance may create an over draft situation Overdraft condition may create over firing Over firing may ignite creosote and or damage appliance and chimney WARNING I Zero Clearance Fireplace A permit may be required for installations final approval is contingent of the authority having local jurisdiction Consult insurance carrier local building fire officials or autho...

Page 19: ...ed the length of the vertical height of the exhaust flue Fire will not burn properly Smoke spillage occurs when door is opened due to air starvation WARNING If Not Installing the Outside Air Kit 1 Swing grille down to expose the two screws Figure 19 1 2 Remove the two screws and pull the access assembly away from the appliance 3 Remove the outside air cover plate A and discard 4 Re install the acc...

Page 20: ...butor or from your local Quadra Fire dealer Part Number DV 6DLR E15ADSS Figure 20 2 shows a vertical installation and also how to create an optional 30 elbow installation The 15 elbow may be secured directly to the flue collar Follow the pipe manufacturer s instructions for using screws or rivets for attachment Most pipe manufacturer s 6 inch 152mm diameter flue liners may be attached directly to ...

Page 21: ...nd baffle protection channel F Surround Trim Kit Installation Standard Size 43 in W x 31 in H Large Size 51 in W x 34 in H 1 Lay surround face down on a protected surface to pre vent scratching 2 Using a 4 to 6 inches long Phillips head screw driver attach the side surrounds to the top surround using 2 8 sheet metal screws on each side provided with the kit Figure 21 3 3 Lay the trim face down and...

Page 22: ... 6 Secure the magnet to the bracket and attach the magnet and bracket to each metal side piece at the bottom The magnet G Standard Surround Cast Trim Kit 4 Felt Vibration Insulation Pads Secure Surrounds to Cast Trim Kit Attach Magnet before installing Cast Footers Magnet Installed Cast Footers Left Right Figure 22 1 Back of Side Piece Magnet Attached Faces Front Clearance Notch is facing the fron...

Page 23: ...he surround to the appliance 2 screws DO NOT OVERTIGHTEN SCREWS MAY DAMAGE PORCELAIN FINISH H All Cast Surround Kit 4 Mounting Brackets Mounting Brackets Attach to Appliance with Screws Remove and Reposition Side Shield using Second Hole Do not overtighten may damage porcelain finish Figure 23 1 Figure 23 2 I Blower Cord Installation on Left Side The blower cord is shipped to be installed on the r...

Page 24: ... screws at the top of the control plate Push the bottom of the control plate to the inside of the appliance and partially remove the control plate assembly White Wire Black Wire Figure 24 2 5 Locate the black and white wires that are part of the power cord and disconnect those wires from the wire harness Green Grounding Wire Remove Screw 6 Remove the screw that is holding the ground lug to the con...

Page 25: ... Connect the white wire on the power cord into the fiber wrapped wire on the wire harness Connect the black wire on the power cord to the white wire on the rheostat Re attach the green ground terminal to the control plate 12 Insert the control plate assembly back into the appliance as shown Tilt the assembly forward and then lift up and rotate the bottom towards the front of the appliance at the s...

Page 26: ...s from each side of insert and use plumbers tape to secure to structure a washer may be required Re install bolts 3 Unit must be grounded with 8 solid copper grounding wire or equivalent and terminated at each end with N E C approved grounding device 4 The factory built fireplace must meet UM 84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must b...

Page 27: ...t Black TRIMKIT 5134 BK Gold TRIMKIT 5134 GD Nickel TRIMKIT 5134 NL Surround Cast Metal Standard SP VOYA CM STD Surround Cast Metal Large SP VOYA CM LRG Cast Trim Black 811 0930 Porcelain Mahogany 811 0960 Surround Complete Cast Matte Black SP VOYA CC MBK Surround Complete Cast Porcelain Mahogany SP VOYA CC PMH DESCRIPTION COMMENTS PART NUMBER STOCKED at DEPOT A Accessory List 7 Accessory List ...

Page 28: ...28 7063 513E August 3 2015 VOYAGEUR B Service and Maintenance Log Date of Service Performed By Description of Service ...

Page 29: ...August 3 2015 7063 513E 29 VOYAGEUR ...

Page 30: ...30 7063 513E August 3 2015 VOYAGEUR ...

Page 31: ...August 3 2015 7063 513E 31 VOYAGEUR ...

Page 32: ...Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This produc...

Reviews: