background image

2

04/21

7058-805F

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2020 particulate emission standards at 1.0 g/hr EPA method 28R and ASTM 2779.

This wood heater needs periodic inspection and repair for proper operation.  Consult the owner’s manual for further information.  It is against federal 

regulations to operate this wood heater in a manner inconsistent with the operating instructions in the owner’s manual.

7058-806A

*Non-combustible floor protection must extend 

2 inches (51mm) 

beneath 

the flue pipe when installed with horizontal venting

 or under the Top Vent 

Adapter with vertical installation. 

RECOMMENDED IN USA; REQUIRED 

IN CANADA.

*Un protecteur incombustible de plancher doit s'étendre 2 inches (51mm) sous le 

conduit de cheminée pour une installation de ventilation horizontale ou sous un 

adapteur de ventilation de dessus pour une installation verticale. 

ÉTATS-UNIS - 

RECOMMANDÉ; CANADA - REQUIRENT.

Floor protector must be non-combustible material, extending beneath 

heater and to the front/sides/rear as indicated. 

Measure front distance (I) 

from the surface of the glass door.

Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, 

comme les schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la 

porte vitrée.

2020 2021 2022

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEP

OCT

NOV

DEC

Manufactured by: Fabriqué par:

352 Mountain House Road

Halifax, Pa 17032

www.quadrafire.com

C# 

4001508

Serial No.

N° de série

HF

BARCODE LABEL

Listed Solid Fuel Room Heater/Pellet Type. Also suitable for Mobile Home Installation.  

This appliance has been tested and listed for use in Manufactured Homes in accordance 

with OAR 814-23-9000 through 814-23-909.

Certified to:

 ASTM STD E1509-04, 

Certified to:

 ULC STD S627-00 Room Heating 

Pellet BurningType, (UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD. Do not use 

any other type of fuel. Intertek-Test Laboratories has determined that this appliance 

complies with Canadian Standards Association (CSA) B415.1 and Title 40 of the U.S. 

Code of Federal Regulations, Part 60, SubPart AAA.

Input Rating:

 

41,900

 Btu's/hr. 

Electrical Rating:

 115 VAC, 60 Hz, Start 3.8 Amps, Run 1.3 

AMPS. Route power cord away from unit. Do not route cord under or in front of 

appliance. Do not obstruct the space beneath the heater.

DANGER

: Risk of electrical shock. Disconnect power supply before servicing. Replace 

glass only with 5mm ceramic available from your dealer. To start, set thermostat above 

room temperature, the stove will light automatically. To shutdown, set thermostat to below 

room temperature. For further instruction refer to owner's manual.

Keep viewing and ash removal doors tightly closed during operation.

PRÉVENTION DES FEUX DE MAISON

Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le 

bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation 

dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.

AVIS - Pour Les Maisons Mobiles :

 Ne pas installer dans une chambre à coucher. Un tuyau extérieur de 

combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure 

intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.

Référez vous aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une 

cheminée à travers un mur ou un plafond combustibles, et les compensations maximums.

Inspectez et nettoyez la cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un 

autre appareil. Utilisez systèm de ventilation "L" ou "P" diamètre 76mm ou 102mm

Testé à :

 ASTM E1509

-04,

 

Testé à : 

ULC STD S627-00, Room Heating. Pellet Burning Type, (UM) 

84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS. N’utiliser aucun autre genre de combustible. 

Intertek Test Laboratories a déterminé que cet appareil se conforme avec la norme de l’Association 

Canadienne de normalisation (CSA) B415.1 ainsi que le Titre 40 du Code Fédéral de Régulations des 

États-Unis, partie 60, sous-partie AAA.   

Puissance de Rendement :

 

41 900

 

Btu's/hr. 

Puissance Électrique :

 115 VAC, 60 Hz, 

Début 3.8 Amps, Courir 1.3 

Amps, Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de 

l'appareil.  

Ne pas bloquer l’espace au dessous de l’appareil

.

DANGER :

 Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service. 

Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.

Pour allumer, monter la température du thermostat au dessus de la température de la pièce, le poêle s'allumera 

automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la 

pièce. Pour des instructions supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture 

et la porte des cendres fermées hermétiquement durant l'opération.

Appareil de chauffage de combustible solide/de type de boulettes.  

Accepté dans l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour 

l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.

PREVENT HOUSE FIRES

Install and use only in accordance with manufacturer's installation and operating instructions.  

Contact local building or fire officials about restrictions and inspection in our area.

WARNING - FOR MOBILE HOMES:

 Do not install appliance in a sleeping room. An 

outside combustion air inlet must be provided. The structural integrity of the mobile home 

floor, ceiling and walls must be maintained.

Refer to manufacturer's instructions and local codes for precautions required for passing 

chimney through a combustible wall or ceiling. Inspect and clean vent system frequently 

in accordance with manufacturer's instructions.

DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.

Use a 3" or 4" diameter type "L" or "PL" venting system.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / 

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES: 

NOTE 1:

 In residential installations, when using Parts TPVNT-5, (3" - 3" Top Vent Adapter) and 

812-3570 (3" - 6" Offset Adapter) or 811-0720 (3” - 4” Offset Adapter), 24 gauge 6" single wall flue 

connector may be used. / 

REMARQUE 1 :

 Dans les installations résidentielles, lorsque les pièces 

TPVNT-5, (dessus de l'adapteur de ventilation 3 po - 3 po) et 812-3570 (le ressaut de l'adapteur 3 

po - 6 po) ou 811-0720 (le ressaut de l'adapteur 3 po - 4 po), un tuyau connecteur de 6 po pour 

mur simple de calibre 24 peut être utilisé.

NOTE 2:

 In manufactured home installation, when using Part TPVNT-5, (3" - 3" Top Vent Adapter) 

and 812-3570 (3" - 6" Offset Adapter) or 811-0720 (3” - 4” Offset Adapter), use listed double wall 

flue connector.  An Outside Air Kit (Part TPVNT-5), must be used with manufactured home 

installation. / 

REMARQUE 2 :

 Pour l'installation dans les maisons préfabriquées, lorsque les pièces 

TPVNT-5, (dessus de l'adapteur de ventilation 3 po - 3 po) et 812-3570 (le ressaut de l'adapteur 3 

po - 6 po) ou 811-0720 (le ressaut de l'adapteur 3 po - 4 po), utilisez un tuyau connecteur 

enregistré pour mur double. Un assemblage d'air extérieur (Part TPVNT-5), doit être utilisé pour 

l'installation dans les maisons préfabriquées.

Back Wall / 

Mur Arrière

 

2 in [51mm]

Side Wall / 

Mur De Côté 

  

14 in [356mm]

CORNER INSTALLATION / 

NSTALLATION DU COIN 

:

Side Wall / 

Mur De Côté 

  

2 in [51mm]

VERTICAL 3 in. - 3 in. ADAPTER KIT (PART 811-0860) INSTALLATION:

UN ASSEMBLAGE POUR ADAPTEUR 3- 3 in (76-76mm) (PIÈCE 811-0860) POUR INSTALLATION 

VERTICALE:

Pipe to Back Wall / Un Tuyau 

Mur Arrière

 

1 in [25mm]

Side Wall / 

Mur De Côté 

  

14 in [356mm]

Back Wall / Mur Arrière 

6.25 in [159mm]

CORNER INSTALLATION WITH VERTICAL ADAPTER KIT:

INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL:

Side Wall / 

Mur De Côté 

  

2 in [51mm]

ALCOVE INSTALLATION / 

INSTALLATION DE L' ALCÔVE

:

Min. Alcove Height: / 

Une hauteur minimum de l'alcôve 

 

51.75 in [1341mm]

Min. Alcove Side Wall: / 

Une hauteur minimum mur de côté de l'alcôve 

 

14 in [356mm]

Min. Alcove Width / Une épaisseur 

minimum mur de côté de l'alcôve 

50.25 in [1276mm]

Max. Alcove Depth: / 

La profondeur maximum de l'alcôve

 

48 in [1219mm]

Max. Mantle Depth: / Profondeur maximum de la manteau de cheminée 

36 in [914mm]

Top of Unit to Combustibles: / Vue du haut 

des matériaux combustibles 

21 in [533mm] 

USA

G  = 2 in

H* =  2 in

I  = 6 in

CANADA

G  = 203 mm

H* =  51 mm

I  = 152 mm

FLOOR PROTECTION / PROTECTION DU SOL

A

B

C

C

D

E

F

C

C

G

H

I

G

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

0061PS086E

CAUTION

:

 

HOT  WHILE  IN  OPERATION  DO  NOT  TOUCH,  KEEP  CHILDREN  AND 

CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS 

LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER

DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE 

L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION

:

KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM 

THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS

Refer to the Intertek Directory of Building Products (https://bpdirectory.intertek.com) for detailed information.

Reportez-vous au répertoire des produits de construction d'Intertek (https://bpdirectory.intertek.com) pour obtenir des informations détaillées.

PS35-C

R

A. Sample of Serial Number / Safety Label

LOCATION: Back of appliance

NOTE:

 Clearances may only be reduced by means approved by the regulatory 

authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Test Lab 

and Report 

Number

Model Number

Serial Number

Manufacturer 

Date

SAMPLE

Summary of Contents for PS35-C

Page 1: ...contact your dealer or visit www quadrafire com REMARQUE Pour obtenir une traduction fran aise de ce manuel s il vous pla t contacter votre revendeur ou visitez www quadrafire com If the information...

Page 2: ...ure du thermostat en dessous de la temp rature de la pi ce Pour des instructions suppl mentaires r f rez vous au manuel du propri taire Gardez la porte d ouverture et la porte des cendres ferm es herm...

Page 3: ...5 8 2 Operating Instructions A Fire Safety 9 B Non Combustible Materials 9 C Combustible Materials 9 D Fuel Material and Fuel Storage 9 E General Operating Information 10 F Before Your First Fire 10 G...

Page 4: ...on boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baffles 6 years 3 years X...

Page 5: ...overed by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRANTY...

Page 6: ...he wall receptacle Turn the thermostat on Turn the thermostat to o If the feed tube is empty or this is the rst re add a handful of pellets to the re pot Do not add extra fuel to the re pot if the fee...

Page 7: ...w Heating Value efficiency using data collected during EPA emissions tests in accordance with the requirements of CSA B415 1 Weighted average HHV High Heating Value efficiency using data collected dur...

Page 8: ...se a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions WARNING This product and the fuels used to operate...

Page 9: ...an ignite and burn flame proofed or not plastered or non plastered Clinkers Minerals and other non combustible materials such as sand will turn into a hard glass like substance called a clinker when h...

Page 10: ...Select the appropriate setting on the FUEL SELECTION screen on the thermostat wall control The burn rate BTU content and heat output will all vary depending on the fuel selected Storage Wood pellets s...

Page 11: ...ng the top of the control switch in and then adjust the thermostat to its highest setting 5 Look through the hole in the left lower side panel and you will see the red call light on the control box wi...

Page 12: ...ics should be checked again after 5 bags of pellets and adjustments made if necessary K Ignition Cycles 1 At the beginning of each ignition cycle it is normal to see some smoke in the firebox The smok...

Page 13: ...emperature near it If you find that it is uncomfortable some distance away from the thermostat change the setting in order to compensate for this Slide Control Fire Risk Do NOT place combustible objec...

Page 14: ...to the blowers Why are different components cycling on and off in my appliance at random The selector switch on control box may be on the wrong setting Refer to the Reference Materials section of our...

Page 15: ...ly Weekly Every 2 Weeks Monthly Yearly Ash Pan Burning Wood Pellets Every 5 bags of fuel OR X Ash Pan Burning Alternate Fuels Every 1 bag of fuel OR X Ash Removal from Firebox More frequently dependin...

Page 16: ...aning rod and then push it back into place If you have closed the cleaning rod properly pushed all the way in you will not see any of the light color painted area Figure 16 3 e Always have the ash dra...

Page 17: ...emove the center baffle first and then the right and left baffles See section on Baffle Instructions on page 26 Thoroughly vacuum the exhaust path and drop tube and continue throughout the rest of the...

Page 18: ...of the fire pot becomes obscure By Homeowner a Appliance must be completely cool before cleaning glass b Vacuum fly ash from glass and door rope c Use a damp paper towel or any non abrasive glass clea...

Page 19: ...or more frequently depending on Dust Dirt build up By Homeowner or Qualified Service Technician a Be sure the appliance is allowed to cool and has been unplugged b Follow section on Side Curtain Repl...

Page 20: ...ly for creosote build up until experience shows how often you need to clean to be safe Be aware that the hotter the fire the less creosote is deposited and weekly cleaning may be necessary in the mild...

Page 21: ...closed Replace control box Call light on No fire Partially burned fuel in fire pot Fire pot clean out plate not closed Fire pot is dirty missed ignition Check that fire pot clean out plate is fully cl...

Page 22: ...y hopper of fuel Use a wet dry vacuum cleaner to remove remaining fuel from hopper including feed tube Check feed chute for obstructions Loosen 2 screws and jiggle feed assembly Check that set screw i...

Page 23: ...steel baffle from firebox to clean ash from on top of baffle Clean behind rear brick panels Change fuel brand to premium Check that fire pot clean out plate is fully closed Reduce feed rate using feed...

Page 24: ...not contact any moving parts or touch any surfaces that may become hot Figure 24 4 A Side Curtain Replacement 1 Lift the hopper lid up until it locks into place 2 Using a Phillips screwdriver a 3 8 i...

Page 25: ...ap disc to the appliance 6 Re install in reverse Snap Disc 2 Fuel Delivery Interrupt 1 Turn down thermostat let appliance cool completely if running Then unplug appliance before servicing 2 Follow sec...

Page 26: ...h drawer and side panel and re connect the power F Baffle Removal Replace 1 Shut down the appliance by turning down the thermostat and let the appliance completely cool down 2 Remove the center baffle...

Page 27: ...ove the 4 brackets and set aside Figure 27 1 3 Remove old glass and replace with the new glass 4 Re install the brackets using the same screws Figure 27 1 Glass is 5mm thick high temperature heat resi...

Page 28: ...air that ignites the pellets 10 Junction Box And Wiring Harness The junction box is located on the lower left side of the appliance behind the left side panel The junction box and wiring harness are...

Page 29: ...Delivery Interrupt 175 F Snap disc 2 is located on the center of the convection plenum above the convection blower There is an orange and a black wire connected to it This snap disc will turn off the...

Page 30: ...ection blower LOCATED BEHIND LEFT SIDE PANELS Control Box Junction Box Red Call Light Fuse LOCATED BEHIND RIGHT SIDE PANELS Feed Motor Vacuum Switch Combustion Blower Power Outlet Terminal Block Cente...

Page 31: ...31 04 21 7058 805F C Maintenance and Service Log Date of Service Performed By Description of Service...

Page 32: ...32 04 21 7058 805F Date of Service Performed By Description of Service...

Page 33: ...33 04 21 7058 805F Date of Service Performed By Description of Service...

Page 34: ...34 04 21 7058 805F Date of Service Performed By Description of Service...

Page 35: ...rvice Parts R PS35 C Beginning Manufacturing Date Mar 2019 Ending Manufacturing Date Active Part number list on following pages 04 21 Free Standing Pellet Stove 1 2 4 5 6 7 3 8 9 10 14 15 16 12 13 11...

Page 36: ...8 026 Y 5 Door Assembly SRV7058 014 5 1 Glass Assembly SRV7058 015 Y 5 2 Rope Door 3 4 X 84 832 1680 Y Corner Tape 1 Ft SRV560 437 9 Gasket Glass Tape 3 4 X 1 8 5 Ft 832 0460 Y 5 3 Hinge Pin 1 2 Nicke...

Page 37: ...kg of 10 SRV7000 462 10 Y 14 Ash Pan Assembly SRV7058 013 15 Pedestal Side Qty 2 req SRV7058 153 16 Blower Convection 812 4900 Y 17 Wire Harness SRV7058 150 Y Fuse 7 Amp Junction Box Pkg of 10 812 038...

Page 38: ...umper Rubber Pkg of 12 SRV224 0340 12 Y Baffle Center Back SRV7058 166 Component Pack SRV7058 063 Airwash SRV7058 175 Cleanout Tool 414 1140 Y Harness Thermostat Wire 230 0810 Power Cord 812 1180 Y Th...

Page 39: ...it 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head Pkg of 10 25221A 10 Y Guide Pin Sleeve Pkg of 25 31120 25 Y Hurricane Screw Pkg of 40 SRV2005 861 40 Nut SER FL SMALL 1 4 20 Pkg of 24 226 0...

Page 40: ...tions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you...

Reviews: