1
Quadra-Fire • LOGS-QFI30 Log Instructions • 2221-935 Rev. E • 6/18
Log Set Assembly: LOGS-QFI30FB
Models: QFI30FB, QFI30FB-C, QFI30FB-IFT
LOG PLACEMENT INSTRUCTIONS
Figure 3. Install Glass Rock
Figure 4. Place Log #1
Figure 5. Place Log #2
Figure 1. Logs Installed
GRATE TINES
PILOT BRACKET
LOG PIN
LIGHT TRAYS
GRATE BAR
1
2
5
6
4
3
7
Figure 2. Reference Points for Log Placement
Log #1 (SRV2221-703)
: Position Log #1 as shown in Figure 4. See Figure 2 for additional points of reference. Center the
log over the pilot bracket. Pull the log forward until contact is made with burner.
Log #2 (SRV2221-701)
: Position Log #2 as shown in Figure 5. See Figure 2 and Figure 6 for additional points of reference.
The recessed area on the bottom of the log and the back right corner of the burner top mate.
GLASS ROCK
LOG RESTS
AGAINST BACK
OF FIREBOX
CENTER LOG
OVER PILOT
BRACKET
FLAT SPOT
FOR LOG #6
RECESSED
AREA OF LOG
MATES WITH
BURNER TOP
1
2
SRV2221-703
SRV2221-701
SRV2221-704
SRV2221-707
SRV2221-705
SRV2221-706
SRV2221-702
CAUTION: Logs are fragile, handle with care.
Glass Rock (2201-853)
: Fill each light tray evenly with the glass rock.
WARNING! Risk of Explosion! DO NOT
place glass rock on the burner surface.
DO NOT
place glass rock directly over
burner ports. Improperly placed glass rock interferes with proper burner operation.