Machine components:
IN-360 Series Base
Product Replacement Guide
Average Time Required: 20 minutes
N1. Remove the components from your original machine
Machine Base
Feed Table
Catch Tray
Weighing Platform
LAN Cable
Power Cable
Meter
Ink Cartridge
Remove the Feed Table
(b)
from the left hand side by lifting the machine
(a)
slightly
and sliding the Feed Table downwards to unlock, then detach the Catch Tray
(c)
from
the right hand side
1
6
Disconnect the LAN Cable
(e)
from the left hand
side by pressing and holding down the clip
Disconnect the Power Cable
(f)
from the right
hand side of the machine
7
The machine must be disconnected from
the power supply before continuing to
the next step!
Open the door of the Meter compartment
and slide the Meter
(h)
towards you
8
N2. Unpack your replacement
Remove replacement unit from box. Remove all transit tape
and packaging from replacement machine. Place original unit
back into box ready for collection
1
Caution: Product weighs 9.9kg,
please seek assistance before lifting
Remove the Meter
(h)
9
Please do not connect your
replacement machine to the power
until step N6.2
Remove the Weighing Platform
(d)
connector from the COM PORT at
the rear of the machine
2
Lift the cover of the machine, Press
down on the Cartridge
(g)
below the
word ‘TOP’ until you hear a ‘click’
4
Remove the Ink Cartridge
(g)
5
Remove tabs from
print heads before
inserting into unit!
Lower Weighing Platform release panel at rear of
the machine. Remove the Weighing Platform
(d)
from the top of the machine
3