background image

 

 

WP2P Digital

 

 

User Guide 

WP2P Digital 

Version 1.7 

Summary of Contents for WP2P Digital & Analogue

Page 1: ...WP2P Digital User Guide WP2P Digital Version 1 7 ...

Page 2: ...ntenna 7 Power Supply Notes 8 Power Supply 8 Internal Fuse 8 Current Consumption Standby Battery Capacity 8 Adjustments Settings 8 HOLD switch Output Relay Configuration 8 REPT switch Repeater Configuration 8 Radio Address RA 9 Using Multiple WP2P Systems in the same area 9 Operation Notes 10 How do the modules communicate 10 STAT Indicator 10 Link Status Indicator 10 MODE Pushbutton Switch 10 Tec...

Page 3: ...ation contained herein is assumed to be accurate QTech Data Systems Limited assumes no responsibility for any errors or omissions Contact QTech QTech Data Systems Limited 12 Midas Place Middleton Christchurch 8024 New Zealand Phone 64 3 366 3713 Fax 64 3 365 2815 Email support qtech co nz Web www qtech co nz Revision Details 1 1 February 2015 First Edition 1 2 May 2015 Minor error corrections 1 3 ...

Page 4: ...ed to link electrical devices together in situations where the physical separation or terrain between them would make direct wiring uneconomic or impractical The most basic WP2P system comprises two WP2P modules which have been configured as a pair The modules simply use their onboard radios to communicate their input state to the other module Each WP2P Low Power DIGITAL module has three switch in...

Page 5: ...e other module will close and when the switch is released the relay will open again WP2P Module 1 Close switch contact on INP1 WP2P Module 2 RLY1 closes operating light The delay between an input activating and the corresponding output activating is normally less than 1 second see note at end Output Relays The output state of each WP2P on loss of communication between the pair can be configured to...

Page 6: ... be connected to the inputs No external voltage or other electrical source is to be connected to the inputs WP2P Repeater Module A WP2P Repeater Module is available to increase the range and coverage of a WP2P system It is used in situations where the WP2P modules are a long way apart or there is an obstacle preventing line of sight between them The WP2P Repeater Module operates by listening for c...

Page 7: ...Qty 4x M4 fixing holes at 102mm x 50mm centres Where the device is to be operated outside or in other adverse site conditions then the device should be housed in an appropriate plastic enclosure For outdoor mounting use the RSS01 solar charging environmental enclosure and follow the installation guide for those products Alternatively use a minimum of IP65 rated enclosure to suit the device and any...

Page 8: ... circuit board To access the fuse remove the top cover by carefully prizing it off its retaining dimples Only replace the fuse with an identical type do not use alternatives This fuse will blow if the power supply maximum voltage is exceeded Current Consumption Standby Battery Capacity Solar systems utilising a solar charged battery backup facility are provided by the RSS01 or RSS02 product For sy...

Page 9: ...a given system must have the same first three numbers in their Radio Address The 4th number must be a sequential pair starting from the even number e g 0 1 1 40 0 1 1 41 The Radio Address must be stated for purchasing for WP2P module replacement Using Multiple WP2P Systems in the same area There are ten individual frequency bands referred to as Channel Numbers allowing up to ten WP2P systems to be...

Page 10: ...t flashes 2s interval Unspecified intermittent communications fault A communications failure as occurred recently 4 Short flashes on power up Indicates the device booting after power up or watchdog reset LED should usually then display normal operating mode indication Link Status Indicator WP2P modules have a Link Status LED which is located next to the power connector This is to assist with site ...

Page 11: ...ress Protection IP20 Water contact should be avoided Power Input voltage 6 24V DC Max 28V DC Current 6mA average Internal 500mA fast blow fuse I O WP2P Digital 3 x digital inputs electrically isolated with internal pull up resistor 3 x relay outputs normally open 2A max Indicators STAT operational status and power LINK communications link activity Pushbutton Operating Mode switch Radio Regulatory ...

Page 12: ...ot warrant the suitability of this product for any particular application as the conditions in which it is used are beyond our control This is not withstanding warranty of merchantability Additional Information and Support If you have problems try the following Visit the QTech web site for application notes and guides Refer to the troubleshooting section if one is present in this document Contact ...

Reviews: