QSW-6300 Series Switches Hardware Installation and Reference Guide
Product Overview
15
1.4.5. LED
LED
Panel
Identification
Status
Meaning
System status
LED
Status
Off
The switch is not powered on.
Blinking
green
(3 Hz)
Initialization is in progress.
Continuous blinking indicates a
fault.
Blinking
green (10Hz)
It is used for on-site positioning
of the device, and allows
operation and maintenance
personnel to perform remote
power on and off control.
Solid green
The switch is operational.
Solid yellow
Temperature alarm:
1. The
temperature
of
inlet/outlet vent exceeds the
warning threshold.
2. The power is insufficient for
the system.
Check the working environment
of the switch and power
supplies immediately.
Solid red
1. The temperature of the
inlet/outlet vent exceeds the
warning threshold.
2.
The switch is faulty.
Power supply
status LED
PWR1/PWR2
Off
The power supply module is
not in place or not powered on.
Solid green
The power supply module is
operating normally.
Solid red
The redundant power is faulty
or the AC power cord is not
connected.
MGMT port status
LED
MGMT
Off
The port is not connected.
Solid green
The port is connected at 1000
Mbps.
Blinking
green
The port is receiving or
transmitting data at 1000 Mbps.