Page | 9
you back your ATV or UTV up the uphill to avoid the front wheels lifting on the
uphill.
OPERATING YOUR QTAC
Before Starting Up Your QTAC
• Always wear appropriate eye, ear, and body protection when operating your
QTAC unit.
• Ensure that your QTAC has sufficient water in the water tank prior to operation.
The water level can be checked by viewing the water tank site gauge located on
the side of the water tank (
Figure 1
) If the water tank is low on water, open the
water tank fill tower (
Figure 1
) and fill the water tank with water.
• Check the pump engine fuel (
Figure 3
) and oil levels (
Figure 3
) as needed, fill the
pump engine with fuel and oil as specified in the engine manual that came with
your QTAC. For more information, see the Pump Operation Manual and the
Engine Owner’s Manual.
PUMP OPERATION
Priming the Pump after an Extended Period of Use
The QTAC pumps are a self-priming pump, meaning they do not need to be primed
before every use. However, if the pump is being started after not being in use for more
than 12 hours, it may be necessary to add water to the primer port (
Figure 2)
to ensure
proper suction. To do so, simply pour water into the primer port until it is full, secure the
cap and start the engine.
Tank Fill Requirements:
MAX FILL PRESSURE: 100 PSI
MAX FILL RATE: 150 GPM