32 ©
Copyright 2017 QSAN Technology, Inc. All Right Reserved.
CLI >
temp
Quantity of temperature sensors: 11
Temperature Sensor Value Status HighCrit HighWarn LowWarn LowCrit
---------------------------------------------------------------------------
Ctrl 1 Backend Connector 30C OK 75 65 5 0
Ctrl 1 Location Bottom Right 42C OK 75 65 5 0
Ctrl 1 SAS Wide Port 1 29C OK 75 65 5 0
Ctrl 1 SAS Expander 65C OK 95 90 5 0
Ctrl 2 Backend Connector 30C OK 75 65 5 0
Ctrl 2 Location Bottom Right 41C OK 75 65 5 0
Ctrl 2 SAS Wide Port 1 29C OK 75 65 5 0
Ctrl 2 SAS Expander 65C OK 95 90 5 0
Backplane Location Left 30C OK 70 65 5 0
Backplane Location Middle 34C OK 70 65 5 0
Backplane Location Right 29C OK 70 65 5 0
Table 2-2
Temperature Sensor Description
Column Name
Description
Status
The status of the temperature sensors:
OK: The thermal sensor is present and no error.
CRIT: The thermal sensor detected a critical error condition.
WARN: The thermal sensor detected a warning error condition.
FAIL: The thermal sensor is not accessible.
2.6.2.
Show Voltage Information (volt)
Command
volt
Description
Show the voltage sensors information of the system.
Syntax
volt
Parameters
none