57
If you see the error message shown above, which means your fan module needed to be replaced
immediately. To replace the malfunction fan module, please refer to
chapter 3.4 Replace System Fan
.
After the new fan module is successfully installed, you can see the fan speed displaying its
Revolutions Per Minute(RPM) value on QSM.
10.2.
Replace Power Supply Unit
XCubeNXT comes with two redundant Power Supply Units (PSU) that can be hot swapped it when
the PSU is not functioning. If a PSU or its fan failed to function, you can check the PSU status in two
ways:
1.
On PSU: the PSU LED will turn to color
amber
.
2.
In QSM: Please go to Monitor app
Hardware. The PSU status will show “
Error
” if failed.
You can also check the status by clicking Dashboard on the top right corner on the desktop.
The System Status will also display “
Error
” and its message, “PSU(No.) is not functioning”.