Align the flash module cage to the slot and then push it all the way into the system chassis
until hear a “click” sound (for 2U chassis release tabs of both flash and power modules are
facing upward while installing into the system).
3.
Align the power module cage to the slot and then push it all the way into the system chassis
until hear a “click” sound.
Confirm the Cache-to-Flash Module Installation
After the cache-to-flash modules are installed, you can check the status and information about
cache-to-flash module in the XEVO UI ->
System
->
Arrays
. If the flash module and power
module are properly installed, the status will display
Good
.
Figure 4-17 Cache-to-Flash Module Installed Successfully
4.6.
Removing / Installing Optional Host Cards
If you encounter data connection problems from the host’s side but you don’t know which port
or which host card is with problem, please go to XEVO UI ->
System
->
Data Ports
, it will show
all host cards you have installed. If the host card has fault, all the ports will have a fault and will
show as
Down
. The following figure is the example of one port failed of the 10GbE iSCSI host
card.