ON
1
2
Sensor: 2.75”H x 3.88”W x 1.5”D
Frequency: 319.5MHz
Battery: 3V lithium CR123A (x2)
Operating Temperature: 14°F to 122°F
Detection Range: 20ft Max
Compatible with Qolsys control panels
Supervisory signal interval: 70 min (approximately)
Ceiling
Walls
✓
✓
IQ GLASS S-LINE QUICK INSTALL GUIDE
CHOOSE
INSTALLATION
LOCATION
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
Sensitivity
:
Two dip switches allow you to customize the sensitivity and detection range of the IQ Glass S. The
factory default is set to MAX. Please refer to the table below to customize the sensitivity.
STEP
2
SWITCH
CONFIGURATION
Test Mode:
Place the sensor in test mode by removing the battery tabs or disconnecting the batteries
for 30 seconds. Test mode is active for 5 minutes upon the sensor powering on. The LED
blinks every second when the sensor is in test mode. Please refer to the table below for the
LED indicator guide. This sensor will exit test mode after the first 5 minutes of power up.
SPECIFICATIONS
STEP
1
CONDITION
RED LED
Power Up
Test Mode, event detected
Test Mode, alarm
Working, alarm
Low Battery
Flash 3 times, flash once per second
Flash once per second (slow flashing)
Flash 2 second (quick flashing)
ON 5 seconds
Flash once every 30 seconds
SENSITIVITY
DETECTION RANGE
MAX
MEDIUM
LOW
LOWEST
20ft
1
2
13ft
8ft
5ft
OFF
ON
OFF
OFF
OFF
ON
ON
ON
Mounting Height:
It is recommended the sensor be mounted at least 6.5ft above
the floor. All protected glass must be within a clear line of sight
of the sensor and within the 20ft max range.
LED Indicator Guide: