C
OMMISSIONING
P
ROCEDURE
85
2.Attach a Lambda sensor to the exhaust outlet, at the threaded boss. Turn on the gage and
make sure it is calibrated; the reading should be 20.9.
3. On the Lynx FPC/Config Tab, Set
Head Setpoint to 600°C
and click
Set
.
Figure 12-14 Head Temp Setpoint
4. While commissioning the PowerGen equipped with QEC3.5 the following parameters must
be changed to override the Load-following features of the software. This is mainly to
override the parameters to properly tune the gas valve during commissioning.
5. Under the FPC/Config Tab, Set