(PXODWLRQV
3ULQWHU&RQILJXUDWLRQ
6HWWLQJ1HWZRUN2SWLRQV
For information on options and defaults found in this menu, see chap-
ter 2, “Printer Configuration,” in the
QMS CrownNet System Adminis-
trator’s Guide.
(PXODWLRQV
Use the Administration/Emulations menu to set the parameters for the
available printer emulations. Optional printing emulations appear only
if installed.
»
Note:
To choose an emulation or ESP for a particular interface, use
the appropriate interface menu in the Administration/Communications
menu.
Choices
Normal—Enables standard, ASCII (7-bit) hex protocol. Data is
sent and received in ASCII format. This mode is
recommended if you do not print binary data. It was designed
for data in the printable ASCII range. Print jobs can change
this setting through PostScript operators.
Normal Fixed—Enables standard, ASCII (7-bit) hex protocol.
Print jobs cannot change this setting through PostScript
operators.
Binary—Enables quoted binary communications protocol
(BCP). Print jobs can change this setting through PostScript
operators. Data in the printable ASCII range also prints.
Binary Fixed—Enables binary communications protocol
(BCP). Print jobs cannot alter change this setting through
PostScript operators. Data in the printable ASCII range also
prints.
Default
Normal
Notes
See chapter 5, “Additional Technical Information,” for a full
discussion of PS Protocol.
Summary of Contents for 2060
Page 1: ...QMS 2060 Print System Reference 1800450 001B...
Page 12: ......
Page 13: ...QWURGXFWLRQ Q 7KLV KDSWHU About This Manual on page 1 2 Typographic Conventions on page 1 3...
Page 36: ......
Page 108: ......
Page 164: ......
Page 185: ...RFXPHQW 2SWLRQ RPPDQGV Q 7KLV SSHQGL Supported QMS DOCs on page C 2...
Page 190: ......
Page 195: ...RQILJXUDWLRQ 0HQX Q 7KLV SSHQGL Configuration menu charts...
Page 200: ......